Eaton VPH4-0047-R Configurable Power Inductor
Eaton VPH4-0047-R Configurable Power Inductor

Eaton VPH4-0047-R Configurable Power Inductor

Share
VPH4-0047-R: configurable six-winding inductor transformer, 7.94 uH.
    • Product Details
    • Download

    Eaton VPH4-0047-R Configurable Power Inductor

    VPH4-0047-R at a glance: configurable six-winding inductor transformer, 7.94 uH.

    Key Specifications

    ParameterValue
    Orderable part numberVPH4-0047-R
    Inductance, base winding7.94 uH
    Isat base1.94 A
    Irms base1.41 A
    R base maximum82.8 mOhm
    Volt-time64.6 V-us
    Peak energy10.5 uJ
    Leakage inductance0.156 uH
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4301

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data 4301; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    The ratings on this page are for the base winding with all others open or paralleled as noted. Any other connection changes the effective inductance and current, and the table of configurations is the place to look.

    Within the VPH4 family this is item 1 of 4 in the Eaton catalogue.

    Series Positioning

    The Versa-Pac range runs from a few microhenry to over a millihenry depending on how the six windings are connected, in through-hole and surface-mount bodies.

    • Ratings depend on the winding configuration. Use the table for the connection you actually build.
    • Typical applications: inductors: buck, boost, coupled, choke, filter, resonant, noise filtering, differential, forward, common mode; telematics; led lighting; lcd display; portable media devices.
    • Design note: write the winding connection on the schematic, otherwise the BOM does not define the part.

    Frequently Asked Questions

    How do I get a specific inductance?
    Connect the windings in the configuration that gives it: parallel for the lowest value at the highest current, series for the highest value. The data sheet lists the common configurations and their ratings.

    Can it be used as a transformer?
    Yes, that is the point of the six-winding construction. The turns ratio is set by how many windings you put in series on each side, and the isolation is that of the bobbin, not a reinforced barrier.

    Why is the DCR higher than a dedicated inductor?
    Six windings share one window, so the wire is thinner for the same inductance. The flexibility is paid for in copper loss.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message