Eaton VPH4-0060-R Six-Winding Inductor 10.1 uH
Eaton VPH4-0060-R Six-Winding Inductor 10.1 uH

Eaton VPH4-0060-R Six-Winding Inductor 10.1 uH

Share
VPH4-0060-R: configurable six-winding inductor transformer, 10.1 uH.
    • Product Details
    • Download

    Eaton VPH4-0060-R Six-Winding Inductor 10.1 uH

    VPH4-0060-R at a glance: configurable six-winding inductor transformer, 10.1 uH.

    Ratings at a Glance

    ParameterValue
    Orderable part numberVPH4-0060-R
    Inductance, base winding10.1 uH
    Isat base1.52 A
    Irms base1.41 A
    R base maximum82.8 mOhm
    Volt-time64.6 V-us
    Peak energy8.16 uJ
    Leakage inductance0.156 uH
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4301

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data 4301; the package line above gives the body size where
    the data sheet states it.

    The Figures Explained

    Configurable magnetics trade a little efficiency for flexibility: more windings in the same window means thinner wire, so the DCR is higher than a dedicated part of the same inductance.

    Within the VPH4 family this is item 2 of 4 in the Eaton catalogue.

    Where This Series Fits

    The Versa-Pac range runs from a few microhenry to over a millihenry depending on how the six windings are connected, in through-hole and surface-mount bodies.

    • Ratings depend on the winding configuration. Use the table for the connection you actually build.
    • Typical applications: inductors: buck, boost, coupled, choke, filter, resonant, noise filtering, differential, forward, common mode; telematics; led lighting; lcd display; portable media devices.
    • Design note: write the winding connection on the schematic, otherwise the BOM does not define the part.

    Frequently Asked Questions

    Are the ratings per winding or total?
    The current ratings are per winding for the base connection stated in the table. Paralleling windings adds the currents; series connection keeps the same current but adds the inductance.

    How do I get a specific inductance?
    Connect the windings in the configuration that gives it: parallel for the lowest value at the highest current, series for the highest value. The data sheet lists the common configurations and their ratings.

    How do I get a specific inductance?
    Connect the windings in the configuration that gives it: parallel for the lowest value at the highest current, series for the highest value. The data sheet lists the common configurations and their ratings.

    Shenzhen Gaorunxin Technology Co., Ltd