| Parameter | Value |
|---|---|
| Orderable part number | VPH4-0075-R |
| Inductance, base winding | 12.7 uH |
| Isat base | 1.21 A |
| Irms base | 1.41 A |
| R base maximum | 82.8 mOhm |
| Volt-time | 64.6 V-us |
| Peak energy | 6.55 uJ |
| Leakage inductance | 0.156 uH |
| Package | See dimension drawing in the data sheet |
| Mounting | Surface mount |
| Operating temperature | -40 C to +125 C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4301 |
Outline drawing, winding arrangement and recommended pad layout are on
page 2 of Eaton Technical Data 4301; the package line above gives the body size where
the data sheet states it.
The ratings on this page are for the base winding with all others open or paralleled as noted. Any other connection changes the effective inductance and current, and the table of configurations is the place to look.
Within the VPH4 family this is item 3 of 4 in the Eaton catalogue.
The Versa-Pac range runs from a few microhenry to over a millihenry depending on how the six windings are connected, in through-hole and surface-mount bodies.
How do I get a specific inductance?
Connect the windings in the configuration that gives it: parallel for the lowest value at the highest current, series for the highest value. The data sheet lists the common configurations and their ratings.
Can it be used as a transformer?
Yes, that is the point of the six-winding construction. The turns ratio is set by how many windings you put in series on each side, and the isolation is that of the bobbin, not a reinforced barrier.
Are the ratings per winding or total?
The current ratings are per winding for the base connection stated in the table. Paralleling windings adds the currents; series connection keeps the same current but adds the inductance.