| Parameter | Value |
|---|---|
| Orderable part number | VPH5-0155-R |
| Inductance, base winding | 22.3 uH |
| Isat base | 1.05 A |
| Irms base | 1.7 A |
| R base maximum | 71.1 mOhm |
| Volt-time | 98.4 V-us |
| Peak energy | 8.83 uJ |
| Leakage inductance | 0.235 uH |
| Package | See dimension drawing in the data sheet |
| Mounting | Surface mount |
| Operating temperature | -40 C to +125 C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4301 |
Outline drawing, winding arrangement and recommended pad layout are on
page 2 of Eaton Technical Data 4301; the package line above gives the body size where
the data sheet states it.
A six-winding configurable inductor: the windings can be paralleled for current, series-connected for inductance, or used as a multi-winding transformer. One part covers a wide design space, which is why the data sheet gives base ratings and a table of configurations rather than a single row.
Within the VPH5 family this is item 4 of 4 in the Eaton catalogue.
The Versa-Pac range runs from a few microhenry to over a millihenry depending on how the six windings are connected, in through-hole and surface-mount bodies.
Can it be used as a transformer?
Yes, that is the point of the six-winding construction. The turns ratio is set by how many windings you put in series on each side, and the isolation is that of the bobbin, not a reinforced barrier.
Are the ratings per winding or total?
The current ratings are per winding for the base connection stated in the table. Paralleling windings adds the currents; series connection keeps the same current but adds the inductance.
Can it be used as a transformer?
Yes, that is the point of the six-winding construction. The turns ratio is set by how many windings you put in series on each side, and the isolation is that of the bobbin, not a reinforced barrier.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd