WCL2520-180-R: wire wound chip inductor, 18 uH ±5%, Q 10 at 2.52 MHz, 130 mA rated, DCR 3000 mOhm.
    • Product Details
    • Download

    Eaton WCL2520-180-R 18 uH Wire Wound Chip Inductor

    WCL2520-180-R at a glance: wire wound chip inductor, 18 uH ±5%, Q 10 at 2.52 MHz, 130 mA rated, DCR 3000 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberWCL2520-180-R
    OCL18 uH ±5%
    Q minimum @ test frequency10 @ 2.52 MHz
    SRF minimum20 MHz
    DCR maximum @ +25 °C3000 mOhm
    Rated current (20 °C rise)130 mA
    OCL test frequency2.52 MHz
    OCL test voltage500 mV
    Package2.92 x 2.79 mm, 2.10 mm high
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10930

    Dimensions and Pad Layout

    WCL2520-180-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10930: outline views
    with rated mm dimensions, pad layout and marking.

    What the Numbers Mean

    A wire wound chip inductor is a coil wound on a ceramic or ferrite core with metal end terminals, in a body the size of a resistor. Compared with a multilayer chip of the same size it gives a higher Q and a tighter tolerance, which is why it appears in filters and matching networks rather than only in supply decoupling.

    At the 130 mA rating the winding drops about 390 mV and dissipates 50.7 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 10 at 2.52 MHz with self-resonance at 20 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCL2520 family this is value 21 of 33, in a range from 0.12 to 220 uH.

    Series Positioning

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: industrial connectivity (iot); computing/gaming consoles; smart meters; industrial equipment; machine-to-machine (m2m).
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    What happens above the self-resonant frequency?
    The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.

    Can I place it with a standard chip shooter?
    Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.

    Can I place it with a standard chip shooter?
    Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products