WCL2520-221-R: wire wound chip inductor, 220 uH ±5%, Q 8 at 0.796 MHz, 20 mA rated, DCR 18000 mOhm.
    • Product Details
    • Download

    Eaton WCL2520-221-R 220 uH Wire Wound Chip Inductor

    WCL2520-221-R at a glance: wire wound chip inductor, 220 uH ±5%, Q 8 at 0.796 MHz, 20 mA rated, DCR 18000 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberWCL2520-221-R
    OCL220 uH ±5%
    Q minimum @ test frequency8 @ 0.796 MHz
    SRF minimum2.5 MHz
    DCR maximum @ +25 °C18000 mOhm
    Rated current (20 °C rise)20 mA
    OCL test frequency0.796 MHz
    OCL test voltage500 mV
    Package2.92 x 2.79 mm, 2.10 mm high
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10930

    Dimensions and Pad Layout

    WCL2520-221-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10930: outline views
    with rated mm dimensions, pad layout and marking.

    How to Read These Ratings

    A wire wound chip inductor is a coil wound on a ceramic or ferrite core with metal end terminals, in a body the size of a resistor. Compared with a multilayer chip of the same size it gives a higher Q and a tighter tolerance, which is why it appears in filters and matching networks rather than only in supply decoupling.

    At the 20 mA rating the winding drops about 360 mV and dissipates 7.2 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 8 at 0.796 MHz with self-resonance at 2.5 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCL2520 family this is value 33 of 33, in a range from 0.12 to 220 uH.

    Where This Series Fits

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: industrial connectivity (iot); computing/gaming consoles; smart meters; industrial equipment; machine-to-machine (m2m).
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    Is the automotive version electrically different?
    The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.

    How is Q specified?
    At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.

    What does the rated current mean here?
    It is the current that produces a 20 °C self-temperature rise, not a saturation limit. On a ceramic-core part there is no saturation to speak of, so the thermal figure is the only limit.