| Parameter | Value |
|---|---|
| Orderable part number | WCL2520-3R3-R |
| OCL | 3.3 uH ±5% |
| Q minimum @ test frequency | 12 @ 7.96 MHz |
| SRF minimum | 80 MHz |
| DCR maximum @ +25 °C | 1500 mOhm |
| Rated current (20 °C rise) | 280 mA |
| OCL test frequency | 7.96 MHz |
| OCL test voltage | 500 mV |
| Package | 2.92 x 2.79 mm, 2.10 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +85 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10930 |

Drawing reproduced from Eaton Technical Data 10930: outline views
with rated mm dimensions, pad layout and marking.
Ceramic-core wire wound parts hold their value well with DC bias because there is no magnetic material to saturate. Ferrite-core versions give more inductance per size but start to roll off as the bias current rises.
At the 280 mA rating the winding drops about 420 mV and dissipates 118 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.
Q of 12 at 7.96 MHz with self-resonance at 80 MHz puts the useful band comfortably below the point where the winding capacitance takes over.
Within the WCL2520 family this is value 12 of 33, in a range from 0.12 to 220 uH.
The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.
What happens above the self-resonant frequency?
The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.
How is Q specified?
At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.
Can I place it with a standard chip shooter?
Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.