Eaton WCL2520-4R7-R 4.7 uH RF Chip Inductor, SRF 50 MHz
Eaton WCL2520-4R7-R 4.7 uH RF Chip Inductor, SRF 50 MHz

Eaton WCL2520-4R7-R 4.7 uH RF Chip Inductor, SRF 50 MHz

Share
WCL2520-4R7-R: wire wound chip inductor, 4.7 uH ±5%, Q 12 at 7.96 MHz, 210 mA rated, DCR 1720 mOhm.
    • Product Details
    • Download

    Eaton WCL2520-4R7-R 4.7 uH RF Chip Inductor, SRF 50 MHz

    WCL2520-4R7-R at a glance: wire wound chip inductor, 4.7 uH ±5%, Q 12 at 7.96 MHz, 210 mA rated, DCR 1720 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberWCL2520-4R7-R
    OCL4.7 uH ±5%
    Q minimum @ test frequency12 @ 7.96 MHz
    SRF minimum50 MHz
    DCR maximum @ +25 °C1720 mOhm
    Rated current (20 °C rise)210 mA
    OCL test frequency7.96 MHz
    OCL test voltage500 mV
    Package2.92 x 2.79 mm, 2.10 mm high
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10930

    Mechanical Dimensions & Pad Layout

    WCL2520-4R7-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10930: outline views
    with rated mm dimensions, pad layout and marking.

    Reading the Data Sheet

    This is a wire wound chip inductor for RF and small-signal circuits: tight tolerance, defined Q, and a rated current that is set by a 20 °C self-temperature rise rather than by saturation.

    At the 210 mA rating the winding drops about 361 mV and dissipates 75.9 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 12 at 7.96 MHz with self-resonance at 50 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCL2520 family this is value 14 of 33, in a range from 0.12 to 220 uH.

    Positioning in the Range

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: industrial connectivity (iot); computing/gaming consoles; smart meters; industrial equipment; machine-to-machine (m2m).
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    What does the rated current mean here?
    It is the current that produces a 20 °C self-temperature rise, not a saturation limit. On a ceramic-core part there is no saturation to speak of, so the thermal figure is the only limit.

    Can I place it with a standard chip shooter?
    Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.