| Parameter | Value |
|---|---|
| Orderable part number | WCL2520-560-R |
| OCL | 56 uH ±5% |
| Q minimum @ test frequency | 10 @ 2.52 MHz |
| SRF minimum | 6.5 MHz |
| DCR maximum @ +25 °C | 6000 mOhm |
| Rated current (20 °C rise) | 55 mA |
| OCL test frequency | 2.52 MHz |
| OCL test voltage | 500 mV |
| Package | 2.92 x 2.79 mm, 2.10 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +85 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10930 |

Drawing reproduced from Eaton Technical Data 10930: outline views
with rated mm dimensions, pad layout and marking.
The value is small and the current is modest, so the design question is not saturation but Q and self-resonance. Q is quoted at one test frequency and SRF is the point where the winding capacitance takes over; both have to be read against the band the part actually works in.
At the 55 mA rating the winding drops about 330 mV and dissipates 18.2 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.
Q of 10 at 2.52 MHz with self-resonance at 6.5 MHz puts the useful band comfortably below the point where the winding capacitance takes over.
Within the WCL2520 family this is value 27 of 33, in a range from 0.12 to 220 uH.
The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.
What does the rated current mean here?
It is the current that produces a 20 °C self-temperature rise, not a saturation limit. On a ceramic-core part there is no saturation to speak of, so the thermal figure is the only limit.
Can I place it with a standard chip shooter?
Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.
Is the automotive version electrically different?
The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd