Eaton WCL3225-120-R 12 uH Chip Inductor, Q 10
Eaton WCL3225-120-R 12 uH Chip Inductor, Q 10

Eaton WCL3225-120-R 12 uH Chip Inductor, Q 10

Share
WCL3225-120-R: wire wound chip inductor, 12 uH ±5%, Q 10 at 2.52 MHz, 265 mA rated, DCR 1200 mOhm.
    • Product Details
    • Download

    Eaton WCL3225-120-R 12 uH Chip Inductor, Q 10

    WCL3225-120-R at a glance: wire wound chip inductor, 12 uH ±5%, Q 10 at 2.52 MHz, 265 mA rated, DCR 1200 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberWCL3225-120-R
    OCL12 uH ±5%
    Q minimum @ test frequency10 @ 2.52 MHz
    SRF minimum25 MHz
    DCR maximum @ +25 °C1200 mOhm
    Rated current (20 °C rise)265 mA
    OCL test frequency2.52 MHz
    OCL test voltage500 mV
    Package3.5 x 2.9 mm, 2.25 mm high
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10931

    Mechanical Drawing

    WCL3225-120-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10931: outline views
    with rated mm dimensions, pad layout and marking.

    How to Read These Ratings

    The value is small and the current is modest, so the design question is not saturation but Q and self-resonance. Q is quoted at one test frequency and SRF is the point where the winding capacitance takes over; both have to be read against the band the part actually works in.

    At the 265 mA rating the winding drops about 318 mV and dissipates 84.3 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 10 at 2.52 MHz with self-resonance at 25 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCL3225 family this is value 19 of 39, in a range from 0.12 to 560 uH.

    Where This Series Fits

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: industrial connectivity (iot); computing/gaming consoles; smart meters; industrial equipment; machine-to-machine (m2m).
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.

    How is Q specified?
    At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.

    How is Q specified?
    At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products