WCL3225-151-R: wire wound chip inductor, 150 uH ±5%, Q 8 at 0.796 MHz, 80 mA rated, DCR 9000 mOhm.
    • Product Details
    • Download

    Eaton WCL3225-151-R 150 uH Wire Wound Chip Inductor

    WCL3225-151-R at a glance: wire wound chip inductor, 150 uH ±5%, Q 8 at 0.796 MHz, 80 mA rated, DCR 9000 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberWCL3225-151-R
    OCL150 uH ±5%
    Q minimum @ test frequency8 @ 0.796 MHz
    SRF minimum4 MHz
    DCR maximum @ +25 °C9000 mOhm
    Rated current (20 °C rise)80 mA
    OCL test frequency0.796 MHz
    OCL test voltage500 mV
    Package3.5 x 2.9 mm, 2.25 mm high
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10931

    Mechanical Dimensions & Pad Layout

    WCL3225-151-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10931: outline views
    with rated mm dimensions, pad layout and marking.

    How to Read These Ratings

    The value is small and the current is modest, so the design question is not saturation but Q and self-resonance. Q is quoted at one test frequency and SRF is the point where the winding capacitance takes over; both have to be read against the band the part actually works in.

    At the 80 mA rating the winding drops about 720 mV and dissipates 57.6 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 8 at 0.796 MHz with self-resonance at 4 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCL3225 family this is value 32 of 39, in a range from 0.12 to 560 uH.

    What This Family Is For

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: industrial connectivity (iot); computing/gaming consoles; smart meters; industrial equipment; machine-to-machine (m2m).
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    How is Q specified?
    At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.

    Is the automotive version electrically different?
    The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.