Eaton WCL3225-391-R 390 uH RF Chip Inductor, SRF 2.2 MHz
Eaton WCL3225-391-R 390 uH RF Chip Inductor, SRF 2.2 MHz

Eaton WCL3225-391-R 390 uH RF Chip Inductor, SRF 2.2 MHz

Share
WCL3225-391-R: wire wound chip inductor, 390 uH ±5%, Q 8 at 0.796 MHz, 45 mA rated, DCR 21500 mOhm.
    • Product Details
    • Download

    Eaton WCL3225-391-R 390 uH RF Chip Inductor, SRF 2.2 MHz

    WCL3225-391-R at a glance: wire wound chip inductor, 390 uH ±5%, Q 8 at 0.796 MHz, 45 mA rated, DCR 21500 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberWCL3225-391-R
    OCL390 uH ±5%
    Q minimum @ test frequency8 @ 0.796 MHz
    SRF minimum2.2 MHz
    DCR maximum @ +25 °C21500 mOhm
    Rated current (20 °C rise)45 mA
    OCL test frequency0.796 MHz
    OCL test voltage500 mV
    Package3.5 x 2.9 mm, 2.25 mm high
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10931

    Outline Drawing

    WCL3225-391-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10931: outline views
    with rated mm dimensions, pad layout and marking.

    What the Numbers Mean

    A wire wound chip inductor is a coil wound on a ceramic or ferrite core with metal end terminals, in a body the size of a resistor. Compared with a multilayer chip of the same size it gives a higher Q and a tighter tolerance, which is why it appears in filters and matching networks rather than only in supply decoupling.

    At the 45 mA rating the winding drops about 968 mV and dissipates 43.5 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 8 at 0.796 MHz with self-resonance at 2.2 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCL3225 family this is value 37 of 39, in a range from 0.12 to 560 uH.

    Series Positioning

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: industrial connectivity (iot); computing/gaming consoles; smart meters; industrial equipment; machine-to-machine (m2m).
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    What happens above the self-resonant frequency?
    The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.

    Can I place it with a standard chip shooter?
    Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.

    What happens above the self-resonant frequency?
    The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products