Eaton WCL3225-3R3-R 3.3 uH Wire Wound Chip Inductor
Eaton WCL3225-3R3-R 3.3 uH Wire Wound Chip Inductor

Eaton WCL3225-3R3-R 3.3 uH Wire Wound Chip Inductor

Share
WCL3225-3R3-R: wire wound chip inductor, 3.3 uH ±5%, Q 12 at 7.96 MHz, 380 mA rated, DCR 1100 mOhm.
    • Product Details
    • Download

    Eaton WCL3225-3R3-R 3.3 uH Wire Wound Chip Inductor

    WCL3225-3R3-R at a glance: wire wound chip inductor, 3.3 uH ±5%, Q 12 at 7.96 MHz, 380 mA rated, DCR 1100 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberWCL3225-3R3-R
    OCL3.3 uH ±5%
    Q minimum @ test frequency12 @ 7.96 MHz
    SRF minimum80 MHz
    DCR maximum @ +25 °C1100 mOhm
    Rated current (20 °C rise)380 mA
    OCL test frequency7.96 MHz
    OCL test voltage500 mV
    Package3.5 x 2.9 mm, 2.25 mm high
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10931

    Mechanical Dimensions & Pad Layout

    WCL3225-3R3-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10931: outline views
    with rated mm dimensions, pad layout and marking.

    What the Numbers Mean

    A wire wound chip inductor is a coil wound on a ceramic or ferrite core with metal end terminals, in a body the size of a resistor. Compared with a multilayer chip of the same size it gives a higher Q and a tighter tolerance, which is why it appears in filters and matching networks rather than only in supply decoupling.

    At the 380 mA rating the winding drops about 418 mV and dissipates 159 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 12 at 7.96 MHz with self-resonance at 80 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCL3225 family this is value 12 of 39, in a range from 0.12 to 560 uH.

    What This Family Is For

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: industrial connectivity (iot); computing/gaming consoles; smart meters; industrial equipment; machine-to-machine (m2m).
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    What happens above the self-resonant frequency?
    The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.

    How is Q specified?
    At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.