| Parameter | Value |
|---|---|
| Orderable part number | WCL3225-470-R |
| OCL | 47 uH ±5% |
| Q minimum @ test frequency | 10 @ 2.52 MHz |
| SRF minimum | 10 MHz |
| DCR maximum @ +25 °C | 5200 mOhm |
| Rated current (20 °C rise) | 140 mA |
| OCL test frequency | 2.52 MHz |
| OCL test voltage | 500 mV |
| Package | 3.5 x 2.9 mm, 2.25 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +85 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10931 |

Drawing reproduced from Eaton Technical Data 10931: outline views
with rated mm dimensions, pad layout and marking.
This is a wire wound chip inductor for RF and small-signal circuits: tight tolerance, defined Q, and a rated current that is set by a 20 °C self-temperature rise rather than by saturation.
At the 140 mA rating the winding drops about 728 mV and dissipates 102 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.
Q of 10 at 2.52 MHz with self-resonance at 10 MHz puts the useful band comfortably below the point where the winding capacitance takes over.
Within the WCL3225 family this is value 26 of 39, in a range from 0.12 to 560 uH.
The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.
How is Q specified?
At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.
How is Q specified?
At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.
Can I place it with a standard chip shooter?
Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.
Shenzhen Gaorunxin Technology Co., Ltd