Eaton WCL3225-560-R 56 uH Chip Inductor, Q 10
Eaton WCL3225-560-R 56 uH Chip Inductor, Q 10

Eaton WCL3225-560-R 56 uH Chip Inductor, Q 10

Share
WCL3225-560-R: wire wound chip inductor, 56 uH ±5%, Q 10 at 2.52 MHz, 125 mA rated, DCR 5600 mOhm.
    • Product Details
    • Download

    Eaton WCL3225-560-R 56 uH Chip Inductor, Q 10

    WCL3225-560-R at a glance: wire wound chip inductor, 56 uH ±5%, Q 10 at 2.52 MHz, 125 mA rated, DCR 5600 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberWCL3225-560-R
    OCL56 uH ±5%
    Q minimum @ test frequency10 @ 2.52 MHz
    SRF minimum8 MHz
    DCR maximum @ +25 °C5600 mOhm
    Rated current (20 °C rise)125 mA
    OCL test frequency2.52 MHz
    OCL test voltage500 mV
    Package3.5 x 2.9 mm, 2.25 mm high
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10931

    Mechanical Dimensions & Pad Layout

    WCL3225-560-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10931: outline views
    with rated mm dimensions, pad layout and marking.

    What the Numbers Mean

    A wire wound chip inductor is a coil wound on a ceramic or ferrite core with metal end terminals, in a body the size of a resistor. Compared with a multilayer chip of the same size it gives a higher Q and a tighter tolerance, which is why it appears in filters and matching networks rather than only in supply decoupling.

    At the 125 mA rating the winding drops about 700 mV and dissipates 87.5 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 10 at 2.52 MHz with self-resonance at 8 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCL3225 family this is value 27 of 39, in a range from 0.12 to 560 uH.

    Series Positioning

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: industrial connectivity (iot); computing/gaming consoles; smart meters; industrial equipment; machine-to-machine (m2m).
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.

    What happens above the self-resonant frequency?
    The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.

    Is the automotive version electrically different?
    The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products