WCL3225-R82-R: wire wound chip inductor, 0.82 uH ±5%, Q 20 at 25.2 MHz, 450 mA rated, DCR 300 mOhm.
    • Product Details
    • Download

    Eaton WCL3225-R82-R 0.82 uH RF Chip Inductor, SRF 350 MHz

    WCL3225-R82-R at a glance: wire wound chip inductor, 0.82 uH ±5%, Q 20 at 25.2 MHz, 450 mA rated, DCR 300 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberWCL3225-R82-R
    OCL0.82 uH ±5%
    Q minimum @ test frequency20 @ 25.2 MHz
    SRF minimum350 MHz
    DCR maximum @ +25 °C300 mOhm
    Rated current (20 °C rise)450 mA
    OCL test frequency25.2 MHz
    OCL test voltage500 mV
    Package3.5 x 2.9 mm, 2.25 mm high
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10931

    Mechanical Drawing

    WCL3225-R82-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10931: outline views
    with rated mm dimensions, pad layout and marking.

    How to Read These Ratings

    A wire wound chip inductor is a coil wound on a ceramic or ferrite core with metal end terminals, in a body the size of a resistor. Compared with a multilayer chip of the same size it gives a higher Q and a tighter tolerance, which is why it appears in filters and matching networks rather than only in supply decoupling.

    At the 450 mA rating the winding drops about 135 mV and dissipates 60.8 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 20 at 25.2 MHz with self-resonance at 350 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCL3225 family this is value 5 of 39, in a range from 0.12 to 560 uH.

    Positioning in the Range

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: industrial connectivity (iot); computing/gaming consoles; smart meters; industrial equipment; machine-to-machine (m2m).
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    Can I place it with a standard chip shooter?
    Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.

    Can I place it with a standard chip shooter?
    Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.

    How is Q specified?
    At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.