WCLA1005V1-1R9-R: wire wound chip inductor, 1.9 nH ±10%, Q 16 at 250 MHz, 1040 mA rated, DCR 70 mOhm.
    • Product Details
    • Download

    Eaton WCLA1005V1-1R9-R 1.9 nH Wire Wound Chip Inductor

    WCLA1005V1-1R9-R at a glance: wire wound chip inductor, 1.9 nH ±10%, Q 16 at 250 MHz, 1040 mA rated, DCR 70 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberWCLA1005V1-1R9-R
    OCL1.9 nH ±10%
    Q minimum @ test frequency16 @ 250 MHz
    SRF minimum6000 MHz
    DCR maximum @ +25 °C70 mOhm
    Rated current (20 °C rise)1040 mA
    OCL test frequency250 MHz
    OCL test voltage500 mV
    Package1.19 x 0.66 mm, 0.60 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10981

    Mechanical Dimensions & Pad Layout

    WCLA1005V1-1R9-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10981: outline views
    with rated mm dimensions, pad layout and marking.

    What the Numbers Mean

    The value is small and the current is modest, so the design question is not saturation but Q and self-resonance. Q is quoted at one test frequency and SRF is the point where the winding capacitance takes over; both have to be read against the band the part actually works in.

    At the 1040 mA rating the winding drops about 72.8 mV and dissipates 75.7 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 16 at 250 MHz with self-resonance at 6000 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA1005V1 family this is value 4 of 52, in a range from 1 to 120 nH.

    What This Family Is For

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.

    Is the automotive version electrically different?
    The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.

    How is Q specified?
    At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.