WCLA1005V1-2R7-R: wire wound chip inductor, 2.7 nH ±10%, Q 15 at 250 MHz, 640 mA rated, DCR 120 mOhm.
    • Product Details
    • Download

    Eaton WCLA1005V1-2R7-R 2.7 nH RF Chip Inductor, SRF 6000 MHz

    WCLA1005V1-2R7-R at a glance: wire wound chip inductor, 2.7 nH ±10%, Q 15 at 250 MHz, 640 mA rated, DCR 120 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberWCLA1005V1-2R7-R
    OCL2.7 nH ±10%
    Q minimum @ test frequency15 @ 250 MHz
    SRF minimum6000 MHz
    DCR maximum @ +25 °C120 mOhm
    Rated current (20 °C rise)640 mA
    OCL test frequency250 MHz
    OCL test voltage500 mV
    Package1.19 x 0.66 mm, 0.60 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10981

    Dimensions and Pad Layout

    WCLA1005V1-2R7-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10981: outline views
    with rated mm dimensions, pad layout and marking.

    Reading the Data Sheet

    This is a wire wound chip inductor for RF and small-signal circuits: tight tolerance, defined Q, and a rated current that is set by a 20 °C self-temperature rise rather than by saturation.

    At the 640 mA rating the winding drops about 76.8 mV and dissipates 49.2 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 15 at 250 MHz with self-resonance at 6000 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA1005V1 family this is value 9 of 52, in a range from 1 to 120 nH.

    Where This Series Fits

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.

    How is Q specified?
    At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.

    Can I place it with a standard chip shooter?
    Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.