WCLA1005V1-5R1-R: wire wound chip inductor, 5.1 nH ±5%, Q 18 at 250 MHz, 800 mA rated, DCR 83 mOhm.
    • Product Details
    • Download

    Eaton WCLA1005V1-5R1-R 5.1 nH Wire Wound Chip Inductor

    WCLA1005V1-5R1-R at a glance: wire wound chip inductor, 5.1 nH ±5%, Q 18 at 250 MHz, 800 mA rated, DCR 83 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberWCLA1005V1-5R1-R
    OCL5.1 nH ±5%
    Q minimum @ test frequency18 @ 250 MHz
    SRF minimum4800 MHz
    DCR maximum @ +25 °C83 mOhm
    Rated current (20 °C rise)800 mA
    OCL test frequency250 MHz
    OCL test voltage500 mV
    Package1.19 x 0.66 mm, 0.60 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10981

    Mechanical Drawing

    WCLA1005V1-5R1-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10981: outline views
    with rated mm dimensions, pad layout and marking.

    The Figures Explained

    Ceramic-core wire wound parts hold their value well with DC bias because there is no magnetic material to saturate. Ferrite-core versions give more inductance per size but start to roll off as the bias current rises.

    At the 800 mA rating the winding drops about 66.4 mV and dissipates 53.1 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 18 at 250 MHz with self-resonance at 4800 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA1005V1 family this is value 16 of 52, in a range from 1 to 120 nH.

    What This Family Is For

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    What does the rated current mean here?
    It is the current that produces a 20 °C self-temperature rise, not a saturation limit. On a ceramic-core part there is no saturation to speak of, so the thermal figure is the only limit.

    Is the automotive version electrically different?
    The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.

    How is Q specified?
    At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.