Eaton WCLA1005V1-5R6-R 5.6 nH RF Chip Inductor, SRF 4800 MHz
Eaton WCLA1005V1-5R6-R 5.6 nH RF Chip Inductor, SRF 4800 MHz

Eaton WCLA1005V1-5R6-R 5.6 nH RF Chip Inductor, SRF 4800 MHz

Share
WCLA1005V1-5R6-R: wire wound chip inductor, 5.6 nH ±5%, Q 20 at 250 MHz, 760 mA rated, DCR 83 mOhm.
    • Product Details
    • Download

    Eaton WCLA1005V1-5R6-R 5.6 nH RF Chip Inductor, SRF 4800 MHz

    WCLA1005V1-5R6-R at a glance: wire wound chip inductor, 5.6 nH ±5%, Q 20 at 250 MHz, 760 mA rated, DCR 83 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberWCLA1005V1-5R6-R
    OCL5.6 nH ±5%
    Q minimum @ test frequency20 @ 250 MHz
    SRF minimum4800 MHz
    DCR maximum @ +25 °C83 mOhm
    Rated current (20 °C rise)760 mA
    OCL test frequency250 MHz
    OCL test voltage500 mV
    Package1.19 x 0.66 mm, 0.60 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10981

    Mechanical Drawing

    WCLA1005V1-5R6-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10981: outline views
    with rated mm dimensions, pad layout and marking.

    Reading the Data Sheet

    Ceramic-core wire wound parts hold their value well with DC bias because there is no magnetic material to saturate. Ferrite-core versions give more inductance per size but start to roll off as the bias current rises.

    At the 760 mA rating the winding drops about 63.1 mV and dissipates 47.9 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 20 at 250 MHz with self-resonance at 4800 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA1005V1 family this is value 17 of 52, in a range from 1 to 120 nH.

    Series Positioning

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.

    What happens above the self-resonant frequency?
    The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.

    Shenzhen Gaorunxin Technology Co., Ltd