Eaton WCLA1005V1-680-R 68 nH Wire Wound Chip Inductor
Eaton WCLA1005V1-680-R 68 nH Wire Wound Chip Inductor

Eaton WCLA1005V1-680-R 68 nH Wire Wound Chip Inductor

Share
WCLA1005V1-680-R: wire wound chip inductor, 68 nH ±5%, Q 25 at 250 MHz, 100 mA rated, DCR 1120 mOhm.
    • Product Details
    • Download

    Eaton WCLA1005V1-680-R 68 nH Wire Wound Chip Inductor

    WCLA1005V1-680-R at a glance: wire wound chip inductor, 68 nH ±5%, Q 25 at 250 MHz, 100 mA rated, DCR 1120 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberWCLA1005V1-680-R
    OCL68 nH ±5%
    Q minimum @ test frequency25 @ 250 MHz
    SRF minimum1620 MHz
    DCR maximum @ +25 °C1120 mOhm
    Rated current (20 °C rise)100 mA
    OCL test frequency250 MHz
    OCL test voltage500 mV
    Package1.19 x 0.66 mm, 0.60 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10981

    Outline Drawing

    WCLA1005V1-680-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10981: outline views
    with rated mm dimensions, pad layout and marking.

    What the Numbers Mean

    The value is small and the current is modest, so the design question is not saturation but Q and self-resonance. Q is quoted at one test frequency and SRF is the point where the winding capacitance takes over; both have to be read against the band the part actually works in.

    At the 100 mA rating the winding drops about 112 mV and dissipates 11.2 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 25 at 250 MHz with self-resonance at 1620 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA1005V1 family this is value 48 of 52, in a range from 1 to 120 nH.

    Positioning in the Range

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    How is Q specified?
    At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.

    What happens above the self-resonant frequency?
    The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.

    What happens above the self-resonant frequency?
    The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message