Eaton WCLA1608V1-101-R 100 nH Wire Wound Chip Inductor
Eaton WCLA1608V1-101-R 100 nH Wire Wound Chip Inductor

Eaton WCLA1608V1-101-R 100 nH Wire Wound Chip Inductor

Share
WCLA1608V1-101-R: wire wound chip inductor, 100 nH ±5%, Q 30 at 150 MHz, 400 mA rated, DCR 630 mOhm.
    • Product Details
    • Download

    Eaton WCLA1608V1-101-R 100 nH Wire Wound Chip Inductor

    WCLA1608V1-101-R at a glance: wire wound chip inductor, 100 nH ±5%, Q 30 at 150 MHz, 400 mA rated, DCR 630 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberWCLA1608V1-101-R
    OCL100 nH ±5%
    Q minimum @ test frequency30 @ 150 MHz
    SRF minimum1400 MHz
    DCR maximum @ +25 °C630 mOhm
    Rated current (20 °C rise)400 mA
    OCL test frequency150 MHz
    OCL test voltage500 mV
    Package1.78 x 1.10 mm, 0.95 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10982

    Dimensions and Pad Layout

    WCLA1608V1-101-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10982: outline views
    with rated mm dimensions, pad layout and marking.

    How to Read These Ratings

    A wire wound chip inductor is a coil wound on a ceramic or ferrite core with metal end terminals, in a body the size of a resistor. Compared with a multilayer chip of the same size it gives a higher Q and a tighter tolerance, which is why it appears in filters and matching networks rather than only in supply decoupling.

    At the 400 mA rating the winding drops about 252 mV and dissipates 101 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 30 at 150 MHz with self-resonance at 1400 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA1608V1 family this is value 23 of 31, in a range from 1.6 to 470 nH.

    Where This Series Fits

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    What does the rated current mean here?
    It is the current that produces a 20 °C self-temperature rise, not a saturation limit. On a ceramic-core part there is no saturation to speak of, so the thermal figure is the only limit.

    Is the automotive version electrically different?
    The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.

    What does the rated current mean here?
    It is the current that produces a 20 °C self-temperature rise, not a saturation limit. On a ceramic-core part there is no saturation to speak of, so the thermal figure is the only limit.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products