Eaton WCLA1608V1-7R5-R 7.5 nH Inductor, 700 mA Rated
Eaton WCLA1608V1-7R5-R 7.5 nH Inductor, 700 mA Rated

Eaton WCLA1608V1-7R5-R 7.5 nH Inductor, 700 mA Rated

Share
WCLA1608V1-7R5-R: wire wound chip inductor, 7.5 nH ±5%, Q 28 at 250 MHz, 700 mA rated, DCR 110 mOhm.
    • Product Details
    • Download

    Eaton WCLA1608V1-7R5-R 7.5 nH Inductor, 700 mA Rated

    WCLA1608V1-7R5-R at a glance: wire wound chip inductor, 7.5 nH ±5%, Q 28 at 250 MHz, 700 mA rated, DCR 110 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberWCLA1608V1-7R5-R
    OCL7.5 nH ±5%
    Q minimum @ test frequency28 @ 250 MHz
    SRF minimum4800 MHz
    DCR maximum @ +25 °C110 mOhm
    Rated current (20 °C rise)700 mA
    OCL test frequency250 MHz
    OCL test voltage500 mV
    Package1.78 x 1.10 mm, 0.95 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10982

    Mechanical Drawing

    WCLA1608V1-7R5-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10982: outline views
    with rated mm dimensions, pad layout and marking.

    The Figures Explained

    This is a wire wound chip inductor for RF and small-signal circuits: tight tolerance, defined Q, and a rated current that is set by a 20 °C self-temperature rise rather than by saturation.

    At the 700 mA rating the winding drops about 77 mV and dissipates 53.9 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 28 at 250 MHz with self-resonance at 4800 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA1608V1 family this is value 9 of 31, in a range from 1.6 to 470 nH.

    Where This Series Fits

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    What does the rated current mean here?
    It is the current that produces a 20 °C self-temperature rise, not a saturation limit. On a ceramic-core part there is no saturation to speak of, so the thermal figure is the only limit.

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products