Eaton WCLA2012V1-151-R 150 nH Chip Inductor, Q 45
Eaton WCLA2012V1-151-R 150 nH Chip Inductor, Q 45

Eaton WCLA2012V1-151-R 150 nH Chip Inductor, Q 45

Share
WCLA2012V1-151-R: wire wound chip inductor, 150 nH ±5%, Q 45 at 250 MHz, 400 mA rated, DCR 560 mOhm.
    • Product Details
    • Download

    Eaton WCLA2012V1-151-R 150 nH Chip Inductor, Q 45

    WCLA2012V1-151-R at a glance: wire wound chip inductor, 150 nH ±5%, Q 45 at 250 MHz, 400 mA rated, DCR 560 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberWCLA2012V1-151-R
    OCL150 nH ±5%
    Q minimum @ test frequency45 @ 250 MHz
    SRF minimum920 MHz
    DCR maximum @ +25 °C560 mOhm
    Rated current (20 °C rise)400 mA
    OCL test frequency100 MHz
    OCL test voltage500 mV
    Package2.30 x 1.70 mm, 1.52 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10983

    Mechanical Dimensions & Pad Layout

    WCLA2012V1-151-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10983: outline views
    with rated mm dimensions, pad layout and marking.

    How to Read These Ratings

    The value is small and the current is modest, so the design question is not saturation but Q and self-resonance. Q is quoted at one test frequency and SRF is the point where the winding capacitance takes over; both have to be read against the band the part actually works in.

    At the 400 mA rating the winding drops about 224 mV and dissipates 89.6 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 45 at 250 MHz with self-resonance at 920 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA2012V1 family this is value 22 of 36, in a range from 2.2 to 2200 nH.

    Positioning in the Range

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    What does the rated current mean here?
    It is the current that produces a 20 °C self-temperature rise, not a saturation limit. On a ceramic-core part there is no saturation to speak of, so the thermal figure is the only limit.

    Can I place it with a standard chip shooter?
    Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.