WCLA2012V1-181-R: wire wound chip inductor, 180 nH ±5%, Q 45 at 250 MHz, 400 mA rated, DCR 640 mOhm.
    • Product Details
    • Download

    Eaton WCLA2012V1-181-R 180 nH Wire Wound Chip Inductor

    WCLA2012V1-181-R at a glance: wire wound chip inductor, 180 nH ±5%, Q 45 at 250 MHz, 400 mA rated, DCR 640 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberWCLA2012V1-181-R
    OCL180 nH ±5%
    Q minimum @ test frequency45 @ 250 MHz
    SRF minimum870 MHz
    DCR maximum @ +25 °C640 mOhm
    Rated current (20 °C rise)400 mA
    OCL test frequency100 MHz
    OCL test voltage500 mV
    Package2.30 x 1.70 mm, 1.52 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10983

    Dimensions and Pad Layout

    WCLA2012V1-181-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10983: outline views
    with rated mm dimensions, pad layout and marking.

    What the Numbers Mean

    A wire wound chip inductor is a coil wound on a ceramic or ferrite core with metal end terminals, in a body the size of a resistor. Compared with a multilayer chip of the same size it gives a higher Q and a tighter tolerance, which is why it appears in filters and matching networks rather than only in supply decoupling.

    At the 400 mA rating the winding drops about 256 mV and dissipates 102 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 45 at 250 MHz with self-resonance at 870 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA2012V1 family this is value 23 of 36, in a range from 2.2 to 2200 nH.

    Where This Series Fits

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    Is the automotive version electrically different?
    The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.

    Is the automotive version electrically different?
    The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.

    Can I place it with a standard chip shooter?
    Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.