Eaton WCLA2012V1-220-R 22 nH RF Chip Inductor, SRF 2600 MHz
Eaton WCLA2012V1-220-R 22 nH RF Chip Inductor, SRF 2600 MHz

Eaton WCLA2012V1-220-R 22 nH RF Chip Inductor, SRF 2600 MHz

Share
WCLA2012V1-220-R: wire wound chip inductor, 22 nH ±5%, Q 55 at 500 MHz, 500 mA rated, DCR 220 mOhm.
    • Product Details
    • Download

    Eaton WCLA2012V1-220-R 22 nH RF Chip Inductor, SRF 2600 MHz

    WCLA2012V1-220-R at a glance: wire wound chip inductor, 22 nH ±5%, Q 55 at 500 MHz, 500 mA rated, DCR 220 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberWCLA2012V1-220-R
    OCL22 nH ±5%
    Q minimum @ test frequency55 @ 500 MHz
    SRF minimum2600 MHz
    DCR maximum @ +25 °C220 mOhm
    Rated current (20 °C rise)500 mA
    OCL test frequency250 MHz
    OCL test voltage500 mV
    Package2.30 x 1.70 mm, 1.52 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10983

    Mechanical Dimensions & Pad Layout

    WCLA2012V1-220-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10983: outline views
    with rated mm dimensions, pad layout and marking.

    Reading the Data Sheet

    Ceramic-core wire wound parts hold their value well with DC bias because there is no magnetic material to saturate. Ferrite-core versions give more inductance per size but start to roll off as the bias current rises.

    At the 500 mA rating the winding drops about 110 mV and dissipates 55 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 55 at 500 MHz with self-resonance at 2600 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA2012V1 family this is value 12 of 36, in a range from 2.2 to 2200 nH.

    Series Positioning

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.

    What happens above the self-resonant frequency?
    The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.

    How is Q specified?
    At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products