| Parameter | Value |
|---|---|
| Orderable part number | WCLA2012V1-221-R |
| OCL | 220 nH ±5% |
| Q minimum @ test frequency | 40 @ 250 MHz |
| SRF minimum | 850 MHz |
| DCR maximum @ +25 °C | 1050 mOhm |
| Rated current (20 °C rise) | 400 mA |
| OCL test frequency | 100 MHz |
| OCL test voltage | 500 mV |
| Package | 2.30 x 1.70 mm, 1.52 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10983 |

Drawing reproduced from Eaton Technical Data 10983: outline views
with rated mm dimensions, pad layout and marking.
A wire wound chip inductor is a coil wound on a ceramic or ferrite core with metal end terminals, in a body the size of a resistor. Compared with a multilayer chip of the same size it gives a higher Q and a tighter tolerance, which is why it appears in filters and matching networks rather than only in supply decoupling.
At the 400 mA rating the winding drops about 420 mV and dissipates 168 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.
Q of 40 at 250 MHz with self-resonance at 850 MHz puts the useful band comfortably below the point where the winding capacitance takes over.
Within the WCLA2012V1 family this is value 24 of 36, in a range from 2.2 to 2200 nH.
The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.
How is Q specified?
At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.
Why choose wire wound over multilayer?
Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.
What happens above the self-resonant frequency?
The winding capacitance dominates and the part behaves capacitively. Keep the working band, and the harmonics that carry energy, below SRF.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd