| Parameter | Value |
|---|---|
| Orderable part number | WCLA2012V1-2R2-R |
| OCL | 2.2 nH ±10% |
| Q minimum @ test frequency | 50 @ 1500 MHz |
| SRF minimum | 8500 MHz |
| DCR maximum @ +25 °C | 30 mOhm |
| Rated current (20 °C rise) | 800 mA |
| OCL test frequency | 250 MHz |
| OCL test voltage | 500 mV |
| Package | 2.30 x 1.70 mm, 1.52 mm high |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10983 |

Drawing reproduced from Eaton Technical Data 10983: outline views
with rated mm dimensions, pad layout and marking.
Ceramic-core wire wound parts hold their value well with DC bias because there is no magnetic material to saturate. Ferrite-core versions give more inductance per size but start to roll off as the bias current rises.
At the 800 mA rating the winding drops about 24 mV and dissipates 19.2 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.
Q of 50 at 1500 MHz with self-resonance at 8500 MHz puts the useful band comfortably below the point where the winding capacitance takes over.
Within the WCLA2012V1 family this is value 1 of 36, in a range from 2.2 to 2200 nH.
The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.
What does the rated current mean here?
It is the current that produces a 20 °C self-temperature rise, not a saturation limit. On a ceramic-core part there is no saturation to speak of, so the thermal figure is the only limit.
Why choose wire wound over multilayer?
Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.
Can I place it with a standard chip shooter?
Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd