Eaton WCLA2012V1-390-R 39 nH Wire Wound Chip Inductor
Eaton WCLA2012V1-390-R 39 nH Wire Wound Chip Inductor

Eaton WCLA2012V1-390-R 39 nH Wire Wound Chip Inductor

Share
WCLA2012V1-390-R: wire wound chip inductor, 39 nH ±5%, Q 55 at 500 MHz, 500 mA rated, DCR 290 mOhm.
    • Product Details
    • Download

    Eaton WCLA2012V1-390-R 39 nH Wire Wound Chip Inductor

    WCLA2012V1-390-R at a glance: wire wound chip inductor, 39 nH ±5%, Q 55 at 500 MHz, 500 mA rated, DCR 290 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberWCLA2012V1-390-R
    OCL39 nH ±5%
    Q minimum @ test frequency55 @ 500 MHz
    SRF minimum2000 MHz
    DCR maximum @ +25 °C290 mOhm
    Rated current (20 °C rise)500 mA
    OCL test frequency250 MHz
    OCL test voltage500 mV
    Package2.30 x 1.70 mm, 1.52 mm high
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10983

    Mechanical Drawing

    WCLA2012V1-390-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10983: outline views
    with rated mm dimensions, pad layout and marking.

    The Figures Explained

    Ceramic-core wire wound parts hold their value well with DC bias because there is no magnetic material to saturate. Ferrite-core versions give more inductance per size but start to roll off as the bias current rises.

    At the 500 mA rating the winding drops about 145 mV and dissipates 72.5 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 55 at 500 MHz with self-resonance at 2000 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA2012V1 family this is value 15 of 36, in a range from 2.2 to 2200 nH.

    Positioning in the Range

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    Can I place it with a standard chip shooter?
    Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.

    Can I place it with a standard chip shooter?
    Yes, the body and terminals are dimensioned for tape and reel and standard nozzle placement. Check the terminal width against the pad geometry in the drawing.

    Is the automotive version electrically different?
    The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products