Eaton WCLA2520V1-1R5-R 1.5 uH Chip Inductor, Q 12
Eaton WCLA2520V1-1R5-R 1.5 uH Chip Inductor, Q 12

Eaton WCLA2520V1-1R5-R 1.5 uH Chip Inductor, Q 12

Share
WCLA2520V1-1R5-R: wire wound chip inductor, 1.5 uH ±10%, Q 12 at 7.96 MHz, 850 mA rated, DCR 170 mOhm.
    • Product Details
    • Download

    Eaton WCLA2520V1-1R5-R 1.5 uH Chip Inductor, Q 12

    WCLA2520V1-1R5-R at a glance: wire wound chip inductor, 1.5 uH ±10%, Q 12 at 7.96 MHz, 850 mA rated, DCR 170 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberWCLA2520V1-1R5-R
    OCL1.5 uH ±10%
    Q minimum @ test frequency12 @ 7.96 MHz
    SRF minimum100 MHz
    DCR maximum @ +25 °C170 mOhm
    Rated current (20 °C rise)850 mA
    OCL test frequency7.96 MHz
    OCL test voltage500 mV
    Package2.90 x 2.50 mm, 2.10 mm high
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1152

    Outline Drawing

    WCLA2520V1-1R5-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1152: outline views
    with rated mm dimensions, pad layout and marking.

    The Figures Explained

    This is a wire wound chip inductor for RF and small-signal circuits: tight tolerance, defined Q, and a rated current that is set by a 20 °C self-temperature rise rather than by saturation.

    At the 850 mA rating the winding drops about 144 mV and dissipates 123 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.

    Q of 12 at 7.96 MHz with self-resonance at 100 MHz puts the useful band comfortably below the point where the winding capacitance takes over.

    Within the WCLA2520V1 family this is value 3 of 13, in a range from 0.22 to 47 uH.

    What This Family Is For

    The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.

    • The rated current is a 20 °C rise figure, not a saturation limit. In a DC bias application check the inductance at the actual bias before sizing the filter.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antenna tuning.
    • Design note: read Q and SRF at the frequency the part works at, not at the test frequency printed in the table.

    Frequently Asked Questions

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.

    Why choose wire wound over multilayer?
    Q. A wound coil has lower resistance for the same inductance, so Q is higher and the loss in a filter or matching network is lower. The price is size and cost, which is why multilayer parts dominate pure decoupling.

    What does the rated current mean here?
    It is the current that produces a 20 °C self-temperature rise, not a saturation limit. On a ceramic-core part there is no saturation to speak of, so the thermal figure is the only limit.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products