| Parameter | Value |
|---|---|
| Orderable part number | WCLA2520V1-220-R |
| OCL | 22 uH ±10% |
| Q minimum @ test frequency | 12 @ 2.52 MHz |
| SRF minimum | 18 MHz |
| DCR maximum @ +25 °C | 1960 mOhm |
| Rated current (20 °C rise) | 260 mA |
| OCL test frequency | 2.52 MHz |
| OCL test voltage | 500 mV |
| Package | 2.90 x 2.50 mm, 2.10 mm high |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1152 |

Drawing reproduced from Eaton Technical Data ELX1152: outline views
with rated mm dimensions, pad layout and marking.
The value is small and the current is modest, so the design question is not saturation but Q and self-resonance. Q is quoted at one test frequency and SRF is the point where the winding capacitance takes over; both have to be read against the band the part actually works in.
At the 260 mA rating the winding drops about 510 mV and dissipates 132 mW. Both are small enough to ignore in a bias network but not in a high-Q filter.
Q of 12 at 2.52 MHz with self-resonance at 18 MHz puts the useful band comfortably below the point where the winding capacitance takes over.
Within the WCLA2520V1 family this is value 11 of 13, in a range from 0.22 to 47 uH.
The WCL and WCLA families run from 1.0 nH in a 1.19 x 0.66 mm body to 560 uH in 3.5 x 2.9 mm, with Q quoted at a stated test frequency for every row.
How is Q specified?
At one test frequency, given in the table. Q falls away either side of that point, so a part quoted at 25 MHz tells you little about behaviour at 900 MHz.
What does the rated current mean here?
It is the current that produces a 20 °C self-temperature rise, not a saturation limit. On a ceramic-core part there is no saturation to speak of, so the thermal figure is the only limit.
Is the automotive version electrically different?
The construction is the same; the qualification and the temperature range are not. The WCLA parts are AEC-Q200 qualified and rated to +125 °C, the commercial WCL parts to +85 °C.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd