EVQ8612-L-12-00A 3-6V, 12A Synchronous Step-down Converter Evaluation Board QFN3
EVQ8612-L-12-00A 3-6V, 12A Synchronous Step-down Converter Evaluation Board QFN3

EVQ8612-L-12-00A 3-6V, 12A Synchronous Step-down Converter Evaluation Board QFN3

Share
pMPS EVQ8612-L-12-00A — Synchronous Step-down Converter Evaluation Board, 3-6V input, 12 A output, QFN3./p
    • Product Details
    • Download

    EVQ8612-L-12-00A 3-6V, 12A Synchronous Step-down Converter Evaluation Board QFN3

    The MPS EVQ8612-L-12-00A is an evaluation board built around the MPQ8612GL-12 for bench characterisation of the device in its intended topology. It operates from a 3 V to 6 V input and is rated for 12 A. The board carries the device in its QFN3 package.

    The EVQ8612-L-12-00A is an evaluation board for the MPQ8612GL-12, a high efficiency monolithic synchronous step-down converter.

    Key Specifications

    Part NumberEVQ8612-L-12-00A
    Board ForMPQ8612GL-12
    Board TypeEvaluation / demonstration board
    FunctionSynchronous Step-down Converter Evaluation Board
    Input Voltage3 V to 6 V
    Current Rating12 A
    PackageQFN3
    Ordering CodesEVQ8612-L-12-00A

    Features

    • Wide 3V to 6V Operating Input Range
    • 12A Output Current
    • 10mΩ/7.8mΩ Internal Power MOSFETs
    • Proprietary Switching Loss Reduction Technique
    • Adaptive COT for Ultrafast Transient Response
    • 1% Reference Voltage Over -40 to +150 Junction Temperature Range
    • Programmable Soft Start Time
    • Pre-Bias Start up
    • Programmable Switching Frequency from 300kHz to 1MHz.
    • Non-Latch OCP, Non-Latch OVP Protection and Thermal Shutdown

    Evaluation Board

    EVQ8612-L-12-00A evaluation board
    EVQ8612-L-12-00A evaluation board, as published by MPS.

    Applications

    • Telecom System Base Station
    • Networking System
    • Personal Video Recorders
    • Flat Panel Television and Monitors

    Design Notes

    • The board ships in a default configuration; check the jumper and resistor options against the user guide before applying power.
    • Respect the input terminal rating — most faults on evaluation boards come from an supply above the marked limit.
    • Test points on the switching node and output are for a short-ground probe, not for a long oscilloscope lead.
    • Where a GUI is supported, connect the dongle before power-up so the device enumerates on the I²C bus.

    Common Questions

    What input voltage does the EVQ8612-L-12-00A support?
    3 V to 6 V. The rated output is 12 A.
    Which package and ordering codes apply to the EVQ8612-L-12-00A?
    QFN3; order codes include EVQ8612-L-12-00A.
    What are the defining features of the EVQ8612-L-12-00A?
    Wide 3V to 6V Operating Input Range 12A Output Current

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products