JCY-25E Eaton Bussmann 5500V 25A Class E Medium Voltage Fuse
JCY-25E Eaton Bussmann 5500V 25A Class E Medium Voltage Fuse

JCY-25E Eaton Bussmann 5500V 25A Class E Medium Voltage Fuse

Share
pEaton Bussmann JCY-25E, 5500V 25A Class E medium voltage fuse, 60 kAIC interrupting. For transformer, feeder and switchgear protection./p
    • Product Details
    • Download

    JCY-25E Eaton Bussmann 5500V 25A Class E Medium Voltage Fuse

    At a Glance
    • 5500 V rated voltage, 25 A rated current
    • 60 kAIC interrupting rating
    • Class E time-current characteristic
    • Single element

    The Eaton Bussmann JCY-25E is a medium voltage fuse with 5500 V rated voltage, 25 A rated current, 60 kAIC interrupting capacity, carrying a Class E time-current characteristic. Construction is 1 barrel, non indicating.

    Specifications

    General specifications
    Product Length/Depth3 in
    Product Height11.5 in
    Product Width3 in
    Product Weight3.25 lb
    Product specifications
    Amperage Rating25 A
    Fuse indicatorNon Indicating
    ClassClass E
    Barrels1
    ElementSingle
    Interrupt rating60 kAIC
    ConnectionFerrule end x ferrule end
    Packaging typeStandard
    Voltage rating5500 V
    TypeCurrent limiting
    ApplicationMedium voltage transformer primary protection, medium voltage feeder circuit protection, MV switches, medium voltage metal-enclosed switchgear

    Series Selection Table

    JCY-25E series selection table
    Ampere ratings, dimensions and catalog numbers across the Medium Voltage Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Energy and utility distribution
    • Industrial equipment
    • Photovoltaic systems

    Selection Notes

    • Select against the available fault current at the installation point, not the load current — the interrupting rating has to exceed it with margin.
    • E-rated fuses follow a defined melting curve; pairing them with non-E-rated devices in the same feeder breaks coordination.
    • Termination: Ferrule end x ferrule end. Confirm the mating clip or busbar before ordering; ferrule and blade ends are not interchangeable.

    Common Questions

    What are the ratings of the Eaton Bussmann JCY-25E?
    5500 V / 25 A, with a 60 kAIC interrupting rating.
    How much fault current can the JCY-25E interrupt?
    60 kAIC. The available fault current at the installation point must not exceed this value.
    What does Class E mean for the JCY-25E?
    Class E defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How does the JCY-25E connect?
    Ferrule end x ferrule end. Confirm the mating clip, holder or busbar before ordering — ferrule and blade ends are not interchangeable.
    How should I select the JCY-25E for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.