JKS-450 Eaton Bussmann 600V 450A Class J Fuse
JKS-450 Eaton Bussmann 600V 450A Class J Fuse

JKS-450 Eaton Bussmann 600V 450A Class J Fuse

Share
Eaton Bussmann JKS-450, 600V, 450A class j fuse.
    • Product Details
    • Download
    At a Glance
    • Rated current 450A
    • Rated voltage 600V
    • Class J class

    The Eaton Bussmann JKS-450 is a class j fuse rated 600V at 450A. It is used for branch circuits where a compact fuse must still carry a high available fault current. 450A 600V Class J Fuse, Bussmann dual element fuse, Littelfuse Cross Reference.

    Same-Series Models

    ModelCurrentVoltageClass
    JKS-1515A600VACClass J
    JKS-2020A600VACClass J
    JKS-2525A600VACClass J
    JKS-3030A600VACClass J
    JKS-3535A600VACClass J
    JKS-4040A600VACClass J
    JKS-5050A600VACClass J
    JKS-6060A600VACClass J
    JKS-7070A600VClass J
    JKS-9090A600VACClass J
    JKS-100-Fast100A600VACClass J
    JKS-110110A600VClass J
    JKS-125125A600VACClass J
    JKS-150150A600VACClass J
    JKS-175175A600VClass J
    JKS-200200A600VACClass J
    JKS-250-Fast-acting250A600VACClass J
    JKS-300300A600VACClass J
    JKS-350350A600VACClass J
    JKS-400400A600VACClass J
    JKS-450450A600VClass J
    JKS-600600A600VACClass J

    22 models in the JKS family, sorted by rated current.

    Applications

    Branch circuits where a compact fuse must still carry a high available fault current.

    Selection Notes

    Class J is dimensioned so it cannot be replaced by a lower-rated class — that is the point of the rejection feature.

    Confirm the holder is rated for the same interrupting current as the fuse.

    Common Questions

    What is the JKS-450 rated for?

    It is rated 600V at 450A. It is a Class J fuse.

    What class is this fuse?

    Class J.

    Can I replace it with a different class?

    No. Fuse classes differ in dimensions and rejection features, so a different class will not fit the holder and may not provide the same protection.

    What does the interrupting rating mean?

    It is the maximum fault current the fuse can safely interrupt. It must be at least as high as the available fault current at the installation point.

    How do I verify the part number?

    Order by the full catalog number JKS-450; suffixes change the terminal, voltage or package.

    Where can I find the datasheet?

    The manufacturer datasheet is the authority for derating curves, I²t and agency approvals for this catalog number.

    Source: manufacturer catalog page for JKS-450. Verify ratings against the current datasheet before ordering.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products