JKS-90 Eaton Bussmann 600VAC 90A Class J Fuse
JKS-90 Eaton Bussmann 600VAC 90A Class J Fuse

JKS-90 Eaton Bussmann 600VAC 90A Class J Fuse

Share
Eaton Bussmann JKS-90, 600VAC, 90A class j fuse, 200kA interrupting.
    • Product Details
    • Download
    At a Glance
    • Rated current 90A
    • Rated voltage 600VAC
    • Interrupting rating 200kA
    • Class J class

    The Eaton Bussmann JKS-90 is a class j fuse rated 600VAC at 90A and with a 200kA interrupting rating. It is used for branch circuits where a compact fuse must still carry a high available fault current. 90A 600V Class J Fuse, Bussmann Fast Acting Fuse.

    Key Specifications

    Product NameEaton Bussmann Class J Fuse
    BrandCooper Bussmann
    Fuse TypeDual Element Fast Acting Fuse
    Catalog NumberJKS-90
    Rated Amperage90A
    Rated Voltage600VAC
    Product Length4.63 in
    Product Diameter1.13 in
    Product Weight2 lb
    ClassClass J
    Voltage TypeAC
    AlternateA4J90
    ConnectionFerrule end x ferrule end
    SPQ1
    Breaking Capacity200kA
    3D Model / CADContact us
    Typical applicationsPower panelboards • Machinery disconnects
    Agency Information600Vac, UL Listed, Std. 248-8, Class J, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787, CE

    Same-Series Models

    ModelCurrentVoltageClass
    JKS-1515A600VACClass J
    JKS-2020A600VACClass J
    JKS-2525A600VACClass J
    JKS-3030A600VACClass J
    JKS-3535A600VACClass J
    JKS-4040A600VACClass J
    JKS-5050A600VACClass J
    JKS-6060A600VACClass J
    JKS-7070A600VClass J
    JKS-9090A600VACClass J
    JKS-100-Fast100A600VACClass J
    JKS-110110A600VClass J
    JKS-125125A600VACClass J
    JKS-150150A600VACClass J
    JKS-175175A600VClass J
    JKS-200200A600VACClass J
    JKS-250-Fast-acting250A600VACClass J
    JKS-300300A600VACClass J
    JKS-350350A600VACClass J
    JKS-400400A600VACClass J
    JKS-450450A600VClass J
    JKS-600600A600VACClass J

    22 models in the JKS family, sorted by rated current.

    Applications

    Branch circuits where a compact fuse must still carry a high available fault current.

    Selection Notes

    Class J is dimensioned so it cannot be replaced by a lower-rated class — that is the point of the rejection feature.

    Confirm the holder is rated for the same interrupting current as the fuse.

    Common Questions

    What is the JKS-90 rated for?

    It is rated 600VAC at 90A. The interrupting rating is 200kA. It is a Class J fuse.

    What class is this fuse?

    Class J.

    Can I replace it with a different class?

    No. Fuse classes differ in dimensions and rejection features, so a different class will not fit the holder and may not provide the same protection.

    What does the interrupting rating mean?

    It is the maximum fault current the fuse can safely interrupt. It must be at least as high as the available fault current at the installation point.

    How do I verify the part number?

    Order by the full catalog number JKS-90; suffixes change the terminal, voltage or package.

    Where can I find the datasheet?

    The manufacturer datasheet is the authority for derating curves, I²t and agency approvals for this catalog number.