High Temperature soldering: 260°C/10 seconds at terminals
Selection Notes
PPTC devices hold at the rated current and trip on sustained overload; they reset after power is removed, so they protect against faults, not against repeated cycling without thermal margin.
Ambient temperature shifts the hold current — derate above 25 °C using the derating curve, or a device sized at room temperature will nuisance-trip.
Common Questions
Where is the datasheet?
The series PDF is published by Fuzetec and linked at the bottom of this page.