    At a Glance
    • Rated current 1200A
    • Rated voltage 600VAC
    • Class L class

    The Eaton Bussmann KTU-1200-Class is a class l fuse rated 600VAC at 1200A. It is used for service and feeder protection in large distribution equipment. Industrial & Electrical Fuses 600VAC 1200A Fast Acting Limitron.

    Same-Series Models

    ModelCurrentVoltageClass
    KTU-601601A600VACClass L Fuse
    KTU-650650A600VACClass L Fuse
    KTU-700700A600VACClass L Fuse
    KTU-750750A600VACClass L Fuse
    KTU-800800A600VACClass L Fuse
    KTU-801801A600VACClass L Fuse
    KTU-850850A600VACClass L Fuse
    KTU-900-Class900A600VACClass L
    KTU-10001000A600VACClass L Fuse
    KTU-11001100A600VACClass L Fuse
    KTU-1200-Class1200A600VACClass L
    KTU-14001400A600VACClass L Fuse
    KTU-15001500A600VACClass L Fuse
    KTU-16001600A600VACClass L Fuse
    KTU-18001800A600VACClass L Fuse
    KTU-20002000A600VACClass L Fuse
    KTU-20012001A600VACClass L Fuse
    KTU-24002400A600VACClass L Fuse
    KTU-25002500A600VACClass L Fuse
    KTU-30003000A600VACClass L Fuse
    KTU-35003500A600VACClass L Fuse
    KTU-40004000A600VACClass L Fuse
    KTU-50005000A600VACClass L Fuse
    KTU-60006000A600VACClass L Fuse

    24 models in the KTU family, sorted by rated current.

    Applications

    Service and feeder protection in large distribution equipment.

    Common Questions

    What is the KTU-1200-Class rated for?

    It is rated 600VAC at 1200A. It is a Class L fuse.

    What class is this fuse?

    Class L.

    Can I replace it with a different class?

    No. Fuse classes differ in dimensions and rejection features, so a different class will not fit the holder and may not provide the same protection.

    What does the interrupting rating mean?

    It is the maximum fault current the fuse can safely interrupt. It must be at least as high as the available fault current at the installation point.

    How do I verify the part number?

    Order by the full catalog number KTU-1200-Class; suffixes change the terminal, voltage or package.

    Where can I find the datasheet?

    The manufacturer datasheet is the authority for derating curves, I²t and agency approvals for this catalog number.

    Source: manufacturer catalog page for KTU-1200-Class. Verify ratings against the current datasheet before ordering.