Littelfuse 0218001 218 Series 1.0 A 5×20mm Glass Tube Through-Hole Fuse
Littelfuse 0218001 218 Series 1.0 A 5×20mm Glass Tube Through-Hole Fuse

Littelfuse 0218001 218 Series 1.0 A 5×20mm Glass Tube Through-Hole Fuse

Share
pLittelfuse 0218001 — 1 A, 250 V, glass cartridge fuse, 35A@250VAC interrupting./p
    • Product Details
    • Download

    Littelfuse 0218001 218 Series 1.0 A 5×20mm Glass Tube Through-Hole Fuse

    Littelfuse 0218001 218 Series 1.0 A 5×20mm Glass Tube Through-Hole Fuse belongs to the Littelfuse range. It carries 1.0 A, rated 250 VAC, in a glass body.

    Technical Data

    ParameterRating
    ParameterValue
    Manufacturer / SeriesLittelfuse / 218 Series
    Part number0218001
    Fuse characteristictime-delay (T)
    Rated current1.0 A
    Voltage rating250 VAC
    Interrupting rating35A@250VAC
    Nominal cold resistance0.0613 Ω
    Nominal melting I²t6.73 A²·s
    Package / mounting5 × 20 mm glass tube (IEC 60127-2 Sheet 3)
    Operating temperature2 °C
    Agency / environmentalUL 248-14 / IEC 60127-2 compliant, RoHS compliant and lead-free

    Design Notes

    • Interrupting capability is 35A@250VAC — confirm the circuit's prospective fault current stays below this.
    • Glass body lets you inspect the element after a fault.
    • Best kept for lower fault-current circuits where visual diagnosis matters.
    • Working voltage must stay at or below 250 VAC; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 1.0 A to stop nuisance trips — fix the cause instead.

    Where It Is Used

    Typical places this fuse turns up:

    • UPS
    • adapter
    • industrial control
    • lighting
    • appliance
    • surge

    Ordering Details

    Order code 0218001 from Littelfuse, supplied in 5 × 20 mm glass tube (IEC 60127-2 Sheet 3). Confirm the exact suffix before release.

    Common Questions

    What are the ratings of the 0218001?

    1.0 A continuous at 250 VAC, interrupting rating 35A@250VAC.

    Can the 0218001 be used on a higher fault-current circuit?

    No — its interrupting rating is 35A@250VAC. Choose a part whose breaking capacity exceeds the prospective fault current.