Littelfuse 0443004.DR 4 A 443 time-lag (Slo-Blo) SMD Fuse
Littelfuse 0443004.DR 4 A 443 time-lag (Slo-Blo) SMD Fuse

Littelfuse 0443004.DR 4 A 443 time-lag (Slo-Blo) SMD Fuse

Share
pLittelfuse 0443004.DR — 4 A, 250 V, time-delay SMD fuse, 50 A @ 250 VAC; 100 A @ 125 VDC; 500 A @ 60 VDC interrupting./p
    • Product Details
    • Download

    Littelfuse 0443004.DR 4 A 443 time-lag (Slo-Blo) SMD Fuse

    Littelfuse 0443004.DR 4 A 443 time-lag (Slo-Blo) SMD Fuse belongs to the Littelfuse range. It carries 4 A, rated 250 VAC, uses a time-delay element.

    Technical Data

    ParameterRating
    ParameterValue
    Manufacturer / SeriesLittelfuse / 443 Series
    Part number0443004.DR
    Fuse characteristictime-lag (Slo-Blo)
    Rated current4 A
    Voltage rating250 VAC
    Interrupting rating50 A @ 250 VAC; 100 A @ 125 VDC; 500 A @ 60 VDC
    Nominal cold resistance0.016 Ω
    Nominal melting I²t122.5 A²s
    PackageNANO2 high-voltage SMD (approx. 10.1 × 3.1 mm)
    Operating temperature-55 °C to +125 °C
    Agency / environmentalUL Recognized, CSA Certified, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Design Notes

    • Interrupting capability is 50 A @ 250 VAC; 100 A @ 125 VDC; 500 A @ 60 VDC — confirm the circuit's prospective fault current stays below this.
    • Time-delay element rides through motor starting and capacitive inrush without nuisance opening.
    • Startup surges of several times rated current are tolerated for a short window.
    • Working voltage must stay at or below 250 VAC; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 4 A to stop nuisance trips — fix the cause instead.

    Where It Is Used

    Typical places this fuse turns up:

    • EV
    • telecom
    • adapter
    • lighting

    Ordering Details

    Order code 0443004.DR from Littelfuse, supplied in NANO2 high-voltage SMD (approx. 10.1 × 3.1 mm). Confirm the exact suffix before release.

    Common Questions

    What are the ratings of the 0443004.DR?

    4 A continuous at 250 VAC, interrupting rating 50 A @ 250 VAC; 100 A @ 125 VDC; 500 A @ 60 VDC.

    Is the 0443004.DR fast-acting or time-delay?

    It is time-delay. It tolerates short inrush surges.

    Can the 0443004.DR be used on a higher fault-current circuit?

    No — its interrupting rating is 50 A @ 250 VAC; 100 A @ 125 VDC; 500 A @ 60 VDC. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message