Littelfuse 0452010.NRL 10 A 452 time-lag (Slo-Blo) SMD Fuse
Littelfuse 0452010.NRL 10 A 452 time-lag (Slo-Blo) SMD Fuse

Littelfuse 0452010.NRL 10 A 452 time-lag (Slo-Blo) SMD Fuse

Share
pLittelfuse 0452010.NRL — 10 A, 72 V, time-delay SMD fuse, 50 A @ 72 VAC; 50 A @ 60 VDC; 100 A @ 75 VDC interrupting./p
    • Product Details
    • Download

    Littelfuse 0452010.NRL 10 A 452 time-lag (Slo-Blo) SMD Fuse

    The 0452010.NRL from Littelfuse carries 10 A, rated 72 VAC / 75 VDC, uses a time-delay element.

    Technical Data

    ParameterRating
    ParameterValue
    Manufacturer / SeriesLittelfuse / 452 Series
    Part number0452010.NRL
    Fuse characteristictime-lag (Slo-Blo)
    Rated current10 A
    Voltage rating72 VAC / 75 VDC
    Interrupting rating50 A @ 72 VAC; 50 A @ 60 VDC; 100 A @ 75 VDC
    Nominal cold resistance0.0080 Ω
    Nominal melting I²t195.0 A²s
    Package2410 / 6125 NANO2
    Operating temperature-55 °C to +125 °C
    Agency / environmentalUL Recognized, CSA Certified, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Practical Notes

    • Interrupting capability is 50 A @ 72 VAC; 50 A @ 60 VDC; 100 A @ 75 VDC — confirm the circuit's prospective fault current stays below this.
    • Time-delay element rides through motor starting and capacitive inrush without nuisance opening.
    • Startup surges of several times rated current are tolerated for a short window.
    • Working voltage must stay at or below 72 VAC / 75 VDC; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 10 A to stop nuisance trips — fix the cause instead.

    Application Scenarios

    Common installation contexts include:

    • battery
    • EV
    • charging
    • telecom
    • surge

    Buying Notes

    Order code 0452010.NRL from Littelfuse, supplied in 2410 / 6125 NANO2. Confirm the exact suffix before release.

    Questions and Answers

    What are the ratings of the 0452010.NRL?

    10 A continuous at 72 VAC / 75 VDC, interrupting rating 50 A @ 72 VAC; 50 A @ 60 VDC; 100 A @ 75 VDC.

    Is the 0452010.NRL fast-acting or time-delay?

    It is time-delay. It tolerates short inrush surges.

    Can the 0452010.NRL be used on a higher fault-current circuit?

    No — its interrupting rating is 50 A @ 72 VAC; 50 A @ 60 VDC; 100 A @ 75 VDC. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products