Littelfuse 0456030.ER 30 A 456 very fast-acting SMD Fuse
Littelfuse 0456030.ER 30 A 456 very fast-acting SMD Fuse

Littelfuse 0456030.ER 30 A 456 very fast-acting SMD Fuse

Share
pLittelfuse 0456030.ER — 30 A, 65 V, fast-acting SMD fuse, 100 A @ 125 VAC; 300 A @ 65 VDC interrupting./p
    • Product Details
    • Download

    Littelfuse 0456030.ER 30 A 456 very fast-acting SMD Fuse

    Littelfuse 0456030.ER 30 A 456 very fast-acting SMD Fuse belongs to the Littelfuse range. It carries 30 A, rated 65 VDC / 125 VAC, uses a fast-acting element.

    Technical Data

    ParameterRating
    ParameterValue
    Manufacturer / SeriesLittelfuse / 456 Series
    Part number0456030.ER
    Fuse characteristicvery fast-acting
    Rated current30 A
    Voltage rating65 VDC / 125 VAC
    Interrupting rating100 A @ 125 VAC; 300 A @ 65 VDC
    Nominal cold resistance0.00132 Ω
    Nominal melting I²t81 A²s
    Package4012 NANO2 high-current SMD
    Operating temperature-55 °C to +125 °C
    Agency / environmentalUL Recognized, RoHS compliant and lead-free

    Design Notes

    • Interrupting capability is 100 A @ 125 VAC; 300 A @ 65 VDC — confirm the circuit's prospective fault current stays below this.
    • Fast element suits resistive and semiconductor loads rather than motors with high inrush.
    • Because it opens within milliseconds, downstream semiconductors see less let-through energy.
    • Working voltage must stay at or below 65 VDC / 125 VAC; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 30 A to stop nuisance trips — fix the cause instead.

    Where It Is Used

    Typical places this fuse turns up:

    • battery
    • EV
    • telecom
    • server

    Ordering Details

    Order code 0456030.ER from Littelfuse, supplied in 4012 NANO2 high-current SMD. Confirm the exact suffix before release.

    Common Questions

    What are the ratings of the 0456030.ER?

    30 A continuous at 65 VDC / 125 VAC, interrupting rating 100 A @ 125 VAC; 300 A @ 65 VDC.

    Is the 0456030.ER fast-acting or time-delay?

    It is fast-acting. Expect it to open quickly on overload.

    Can the 0456030.ER be used on a higher fault-current circuit?

    No — its interrupting rating is 100 A @ 125 VAC; 300 A @ 65 VDC. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message