Littelfuse 046002.5UR 2.5 A PICO® SMF 460 Fuse, 125 VAC/VDC, SMD terminals, UR
Littelfuse 046002.5UR 2.5 A PICO® SMF 460 Fuse, 125 VAC/VDC, SMD terminals, UR

Littelfuse 046002.5UR 2.5 A PICO® SMF 460 Fuse, 125 VAC/VDC, SMD terminals, UR

Share
pLittelfuse 046002.5UR — 2.5 A, 125 V, SMD fuse, 50 A @ 125 VAC/VDC interrupting./p
    • Product Details
    • Download

    Littelfuse 046002.5UR 2.5 A PICO® SMF 460 Fuse, 125 VAC/VDC, SMD terminals, UR

    Littelfuse 046002.5UR 2.5 A PICO® SMF 460 Fuse, 125 VAC/VDC, SMD terminals, UR belongs to the Littelfuse range. It carries 2.5 A, rated 125 VAC/VDC.

    Technical Data

    ParameterRating
    ParameterValue
    Manufacturer / SeriesLittelfuse / PICO® SMF 460
    Part number046002.5UR
    Fuse characteristicSlo-Blo® / Time-Lag (T)
    Rated current2.5 A
    Rated voltage125 VAC/VDC
    Interrupting capability50 A @ 125 VAC/VDC
    PackagePICO® SMF surface-mount fuse; Tape & Reel
    Mounting methodSurface Mount (SMD)
    Dimensions8.26 × 4.32 × 3.05 mm
    Lead pitchN/A (SMD)
    Operating temperature-55°C to +125°C
    ApprovalsUL E10480; CSA 29862; PSE NBK030205-E10480B
    Standards / complianceUL Recognized; CSA; PSE (1–5A); RoHS
    EnvironmentalRoHS compliant; halogen free
    Nominal cold resistance0.052 Ω
    Nominal melting I²t13 A²s
    Packaging / order codeUR: Tape & Reel, 500 pcs; SMD terminals
    Product statusVerify current orderability with Littelfuse / authorized distribution

    Design Notes

    • Interrupting capability is 50 A @ 125 VAC/VDC — confirm the circuit's prospective fault current stays below this.
    • Working voltage must stay at or below 125 VAC/VDC; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 2.5 A to stop nuisance trips — fix the cause instead.

    Ordering Details

    Order code 046002.5UR from Littelfuse, supplied in PICO® SMF surface-mount fuse; Tape & Reel. Confirm the exact suffix before release.

    Common Questions

    What are the ratings of the 046002.5UR?

    2.5 A continuous at 125 VAC/VDC, interrupting rating 50 A @ 125 VAC/VDC.

    Can the 046002.5UR be used on a higher fault-current circuit?

    No — its interrupting rating is 50 A @ 125 VAC/VDC. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message