Littelfuse 04651.25DR 1.25 A 465 time-lag SMD Fuse
Littelfuse 04651.25DR 1.25 A 465 time-lag SMD Fuse

Littelfuse 04651.25DR 1.25 A 465 time-lag SMD Fuse

Share
pLittelfuse 04651.25DR — 1.25 A, 250 V, time-delay SMD fuse, 100 A @ 250 VAC interrupting./p
    • Product Details
    • Download

    Littelfuse 04651.25DR 1.25 A 465 time-lag SMD Fuse

    The 04651.25DR from Littelfuse carries 1.25 A, rated 250 VAC, uses a time-delay element.

    Technical Data

    ParameterRating
    ParameterValue
    Manufacturer / SeriesLittelfuse / 465 Series
    Part number04651.25DR
    Fuse characteristictime-lag
    Rated current1.25 A
    Voltage rating250 VAC
    Interrupting rating100 A @ 250 VAC
    Nominal cold resistance0.0830 Ω
    Nominal melting I²t5.6 A²s
    Package12.1 × 4.5 mm NANO2 UMF
    Operating temperature-55 °C to +125 °C
    Agency / environmentalIEC 60127-4 UMF, UL/PSE approvals by rating, RoHS compliant and halogen-free

    Practical Notes

    • Interrupting capability is 100 A @ 250 VAC — confirm the circuit's prospective fault current stays below this.
    • Time-delay element rides through motor starting and capacitive inrush without nuisance opening.
    • Startup surges of several times rated current are tolerated for a short window.
    • Working voltage must stay at or below 250 VAC; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 1.25 A to stop nuisance trips — fix the cause instead.

    Application Scenarios

    Common installation contexts include:

    • EV
    • lighting

    Buying Notes

    Order code 04651.25DR from Littelfuse, supplied in 12.1 × 4.5 mm NANO2 UMF. Confirm the exact suffix before release.

    Questions and Answers

    What are the ratings of the 04651.25DR?

    1.25 A continuous at 250 VAC, interrupting rating 100 A @ 250 VAC.

    Is the 04651.25DR fast-acting or time-delay?

    It is time-delay. It tolerates short inrush surges.

    Can the 04651.25DR be used on a higher fault-current circuit?

    No — its interrupting rating is 100 A @ 250 VAC. Choose a part whose breaking capacity exceeds the prospective fault current.