Littelfuse PICO® SMF 459 045902.5ER | 2.5 A 125 VAC/VDC Fuse | SMD terminals | 2,500 pcs
Littelfuse PICO® SMF 459 045902.5ER | 2.5 A 125 VAC/VDC Fuse | SMD terminals | 2,500 pcs

Littelfuse PICO® SMF 459 045902.5ER | 2.5 A 125 VAC/VDC Fuse | SMD terminals | 2,500 pcs

Share
pLittelfuse 045902.5ER — 2.5 A, 125 V, SMD fuse, 50 A @ 125 VAC; 300 A @ 125 VDC interrupting./p
    • Product Details
    • Download

    Littelfuse PICO® SMF 459 045902.5ER | 2.5 A 125 VAC/VDC Fuse | SMD terminals | 2,500 pcs

    The 045902.5ER from Littelfuse carries 2.5 A, rated 125 VAC/VDC.

    Technical Data

    ParameterRating
    ParameterValue
    Manufacturer / SeriesLittelfuse / PICO® SMF 459
    Part number045902.5ER
    Fuse characteristicVery Fast-Acting (FF)
    Rated current2.5 A
    Rated voltage125 VAC/VDC
    Interrupting capability50 A @ 125 VAC; 300 A @ 125 VDC
    PackagePICO® SMF surface-mount fuse; Tape & Reel
    Mounting methodSurface Mount (SMD)
    Dimensions8.26 × 4.32 × 3.05 mm
    Lead pitchN/A (SMD)
    Operating temperature-55°C to +125°C
    ApprovalsUL E10480; CSA 29862; PSE NBK030205-E10480B
    Standards / complianceUL Recognized; CSA (rating-dependent); PSE (1–5A); RoHS
    EnvironmentalRoHS compliant
    Nominal cold resistance0.035 Ω
    Nominal melting I²t0.721 A²s
    Packaging / order codeER: Tape & Reel, 2,500 pcs; SMD terminals
    Product statusVerify current orderability with Littelfuse / authorized distribution

    Practical Notes

    • Interrupting capability is 50 A @ 125 VAC; 300 A @ 125 VDC — confirm the circuit's prospective fault current stays below this.
    • Working voltage must stay at or below 125 VAC/VDC; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 2.5 A to stop nuisance trips — fix the cause instead.

    Application Scenarios

    Common installation contexts include:

    • EV
    • telecom

    Buying Notes

    Order code 045902.5ER from Littelfuse, supplied in PICO® SMF surface-mount fuse; Tape & Reel. Confirm the exact suffix before release.

    Questions and Answers

    What are the ratings of the 045902.5ER?

    2.5 A continuous at 125 VAC/VDC, interrupting rating 50 A @ 125 VAC; 300 A @ 125 VDC.

    Can the 045902.5ER be used on a higher fault-current circuit?

    No — its interrupting rating is 50 A @ 125 VAC; 300 A @ 125 VDC. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd