Littelfuse TR5® 382 38218000410 | 8 A 250 VAC Fuse | Short leads | 1,000 pcs
Littelfuse TR5® 382 38218000410 | 8 A 250 VAC Fuse | Short leads | 1,000 pcs

Littelfuse TR5® 382 38218000410 | 8 A 250 VAC Fuse | Short leads | 1,000 pcs

Share
pLittelfuse 38218000410 — 8 A, 250 V, fuse, 100 A @ 250 VAC interrupting./p
    • Product Details
    • Download

    Littelfuse TR5® 382 38218000410 | 8 A 250 VAC Fuse | Short leads | 1,000 pcs

    Built by Littelfuse, the 38218000410 carries 8 A, rated 250 VAC.

    Technical Data

    ParameterRating
    ParameterValue
    Manufacturer / SeriesLittelfuse / TR5® 382
    Part number38218000410
    Fuse characteristicSlo-Blo® / Time-Lag (T)
    Rated current8 A
    Rated voltage250 VAC
    Interrupting capability100 A @ 250 VAC
    PackageTR5® radial lead fuse; Short leads; Bulk
    Mounting methodThrough Hole, Radial
    DimensionsØ8.5 mm × 8.0 mm max; lead Ø0.6 mm
    Lead pitch5.08 mm
    Operating temperature-40°C to +85°C
    ApprovalscRUus E67006; PSE
    Standards / complianceIEC 60127-3; UL/CSA/NMX 248-1 & 248-14; VDE/CCC/KC (up to 6.3A); cRUus/PSE
    EnvironmentalRoHS; lead-free; halogen-free
    Nominal cold resistance0.0059 Ω
    Nominal melting I²t233.6 A²s
    Packaging / order code0410: Bulk, 1,000 pcs; Short leads; lead length 4.3 mm
    Product statusVerify current orderability with Littelfuse / authorized distribution

    Selection Notes

    • Interrupting capability is 100 A @ 250 VAC — confirm the circuit's prospective fault current stays below this.
    • Working voltage must stay at or below 250 VAC; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 8 A to stop nuisance trips — fix the cause instead.

    Typical Applications

    Engineers usually specify it for these duties:

    • EV

    Part Number and Packing

    Order code 38218000410 from Littelfuse, supplied in TR5® radial lead fuse; Short leads; Bulk. Confirm the exact suffix before release.

    Q&A

    What are the ratings of the 38218000410?

    8 A continuous at 250 VAC, interrupting rating 100 A @ 250 VAC.

    Can the 38218000410 be used on a higher fault-current circuit?

    No — its interrupting rating is 100 A @ 250 VAC. Choose a part whose breaking capacity exceeds the prospective fault current.