MDL-1-1/2-R 1.5 A 250 Vac Time-Delay Glass Cartridge Fuse
MDL-1-1/2-R 1.5 A 250 Vac Time-Delay Glass Cartridge Fuse

MDL-1-1/2-R 1.5 A 250 Vac Time-Delay Glass Cartridge Fuse

Share
pEaton MDL-1-1/2-R — 1.5 A, 250 V, time-delay glass cartridge fuse, 100 A at 250 Vac; 10,000 A at 125 Vac interrupting./p
    • Product Details
    • Download

    MDL-1-1/2-R 1.5 A 250 Vac Time-Delay Glass Cartridge Fuse

    Built by the maker, the MDL-1-1/2-R carries 1.5 A, rated 250 Vac, uses a time-delay element, in a glass body.

    Technical Data

    ParameterRating
    Part numberMDL-1-1/2-R
    Voltage rating250 Vac
    Design standardUL 248-14
    Elementsingle element
    Typical melting I2t22.7 A²s
    BodyGlass tube, 1/4 x 1-1/4 in (6.4 x 31.7 mm)
    Rated current1.5 A (1-1/2 A)
    Typical DC cold resistance0.156 Ω
    AC interrupting rating100 A at 250 Vac; 10,000 A at 125 Vac
    End capsnickel-plated brass
    Typical voltage drop0.721 V

    Selection Notes

    • Interrupting capability is 100 A at 250 Vac; 10,000 A at 125 Vac — confirm the circuit's prospective fault current stays below this.
    • Time-delay element rides through motor starting and capacitive inrush without nuisance opening.
    • Startup surges of several times rated current are tolerated for a short window.
    • Glass body lets you inspect the element after a fault.
    • Best kept for lower fault-current circuits where visual diagnosis matters.
    • Working voltage must stay at or below 250 Vac; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 1.5 A to stop nuisance trips — fix the cause instead.

    Typical Applications

    Engineers usually specify it for these duties:

    • EV

    Q&A

    What are the ratings of the MDL-1-1/2-R?

    1.5 A continuous at 250 Vac, interrupting rating 100 A at 250 Vac; 10,000 A at 125 Vac.

    Is the MDL-1-1/2-R fast-acting or time-delay?

    It is time-delay. It tolerates short inrush surges.

    Can the MDL-1-1/2-R be used on a higher fault-current circuit?

    No — its interrupting rating is 100 A at 250 Vac; 10,000 A at 125 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message