NON-70 Eaton Bussmann 250VAC 70A Class H(K) Fuse
NON-70 Eaton Bussmann 250VAC 70A Class H(K) Fuse

NON-70 Eaton Bussmann 250VAC 70A Class H(K) Fuse

Share
Eaton Bussmann NON-70, 250VAC, 70A class h(k) fuse, 50kA interrupting.
    • Product Details
    • Download
    At a Glance
    • Rated current 70A
    • Rated voltage 250VAC
    • Interrupting rating 50kA
    • Class H class

    The Eaton Bussmann NON-70 is a class h(k) fuse rated 250VAC at 70A and with a 50kA interrupting rating. It is used for older panelboards and switchboards built for renewable or one-time fuses. 70A 250VAC, Class H Fuse, one time fuse, non current limiting fuse, Mersen Cross Reference.

    Key Specifications

    Product NameEaton Bussmann NON Class H fuse
    Catalog NumberNON-70
    Rated Amperage70A
    Rated Voltage250VAC,125VDC
    Product Height5.88 in
    Product Diameter1.06 in
    Product Weight0.5 lb
    ClassClass H
    Voltage TypeAC
    Breaking Capacity50kA
    3D Model / CADstp
    ConnectionBlade end x Blade end
    CertificationUL

    Same-Series Models

    ModelCurrentVoltageClass
    NON-11A250VACClass H
    NON-22A250V—
    NON-66A250VACClass H
    NON-1/21/2A250VACClass H
    NON-4040A250VACClass H
    NON-7070A250VACClass H
    NON-150150A250VACClass H
    NON-200200A250VACClass H
    NON-400400A250VACClass H
    NON-500500A250VACClass H
    NON-600600A250VACClass H
    NON-8/108/10A250VACClass H

    12 models in the NON family, sorted by rated current.

    Standards & Approvals

    UL — as listed by the manufacturer for this catalog number. Confirm the current certificate before design freeze.

    Applications

    Older panelboards and switchboards built for renewable or one-time fuses.

    Common Questions

    What is the NON-70 rated for?

    It is rated 250VAC at 70A. The interrupting rating is 50kA. It is a Class H fuse.

    What class is this fuse?

    Class H.

    Can I replace it with a different class?

    No. Fuse classes differ in dimensions and rejection features, so a different class will not fit the holder and may not provide the same protection.

    What does the interrupting rating mean?

    It is the maximum fault current the fuse can safely interrupt. It must be at least as high as the available fault current at the installation point.

    How do I verify the part number?

    Order by the full catalog number NON-70; suffixes change the terminal, voltage or package.

    Where can I find the datasheet?

    The manufacturer datasheet is the authority for derating curves, I²t and agency approvals for this catalog number.

    Source: manufacturer catalog page for NON-70. Verify ratings against the current datasheet before ordering.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products