NOS-175 Eaton Bussmann 600VAC 175A Class H(K) Fuse
NOS-175 Eaton Bussmann 600VAC 175A Class H(K) Fuse

NOS-175 Eaton Bussmann 600VAC 175A Class H(K) Fuse

Share
Eaton Bussmann NOS-175, 600VAC, 175A class h(k) fuse, 50kA interrupting.
    • Product Details
    • Download
    At a Glance
    • Rated current 175A
    • Rated voltage 600VAC
    • Interrupting rating 50kA
    • Class H class

    The Eaton Bussmann NOS-175 is a class h(k) fuse rated 600VAC at 175A and with a 50kA interrupting rating. It is used for older panelboards and switchboards built for renewable or one-time fuses. 175A 600VAC, Class H Fuse, one time fuse, non current limiting fuse, Class K Fuse.

    Key Specifications

    Product NameEaton Bussmann series NOS fuse Class H Fuse
    Catalog NumberNOS-175
    Rated Amperage175A
    Rated Voltage600VAC
    Product Height9.63 in
    Product Diameter1.84 in
    Product Weight1.2 lb
    ClassClass H
    Voltage TypeAC
    Breaking Capacity50kA
    3D Model / CADstp
    ConnectionBlade end x Blade end
    CertificationUL

    Same-Series Models

    ModelCurrentVoltageClass
    NOS-22A600VACClass H
    NOS-33A600VACClass H
    NOS-44A600VACClass H
    NOS-55A600VACClass H
    NOS-99A600VACClass H
    NOS-1515A600VACClass H
    NOS-5050A600VACClass H
    NOS-6060A600VClass H
    NOS-8080A600VACClass H
    NOS-100100A600VACClass H
    NOS-175175A600VACClass H
    NOS-250250A600VACClass H
    NOS-400400A600VACClass H
    NOS-600600A600VACClass H

    14 models in the NOS family, sorted by rated current.

    Standards & Approvals

    UL — as listed by the manufacturer for this catalog number. Confirm the current certificate before design freeze.

    Applications

    Older panelboards and switchboards built for renewable or one-time fuses.

    Common Questions

    What is the NOS-175 rated for?

    It is rated 600VAC at 175A. The interrupting rating is 50kA. It is a Class H fuse.

    What class is this fuse?

    Class H.

    Can I replace it with a different class?

    No. Fuse classes differ in dimensions and rejection features, so a different class will not fit the holder and may not provide the same protection.

    What does the interrupting rating mean?

    It is the maximum fault current the fuse can safely interrupt. It must be at least as high as the available fault current at the installation point.

    How do I verify the part number?

    Order by the full catalog number NOS-175; suffixes change the terminal, voltage or package.

    Where can I find the datasheet?

    The manufacturer datasheet is the authority for derating curves, I²t and agency approvals for this catalog number.

    Source: manufacturer catalog page for NOS-175. Verify ratings against the current datasheet before ordering.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products