The Eaton Bussmann PV-110ANH1 is a solar pv fuse rated 100VDC at 110A and with a 50kA interrupting rating. It is used for DC string protection in photovoltaic arrays. 110A 1000VDC, Photovoltaic Fuse, NH1, gPV Fuse, dual indicator, Cooper Bussmann.
| Product Name | Eaton Bussmann series photovoltaic fuses |
| Catalog Number | PV-110ANH1 |
| Rated Amperage | 110A |
| Rated Voltage | 100VDC |
| Product Length | 135mm |
| Product Height | 63mm |
| Product Width | 40mm |
| Product Weight | 407g |
| Class | Class gPV |
| Construction | Square Body |
| Voltage Type | DC |
| Package Type | Standard |
| Breaking Capacity | 50kA |
| Fuse Size | NH1 |
| Fuse Holder | SD1-D-PV NH Fuse base |
| 3D Model / CAD | Contact |
| Application | Array Protection |
| Certification | IEC 60269 UL Listed CSA Certified |
| Model | Current | Voltage | Class |
|---|---|---|---|
| PV-2-25A14LF | 2.25A | 1500Vdc | Class gPV |
| PV-2-25A10F85L | 2.25A | 1500V | — |
| PV-2.5A14LF | 2.5A | 1500V | — |
| PV-2.5A10F85L | 2.5A | 1500V | — |
| PV-3A14F | 3A | 1500V | — |
| PV-3.5A10F85L | 3.5A | 1500V | — |
| PV-4A14F | 4A | 1500V | — |
| PV-A14L | 15A | 1500V | — |
| PV-16A10F | 16A | 1000V | — |
| PV-30A10F85L-Solar | 30A | 1500V | — |
| PV-80A-01XL | 80A | 1000V | — |
| PV-110ANH1 | 110A | 100VDC | Class gPV |
| PV-160NH1-B | 160A | 1000V | — |
| PV-175ANH1 | 175A | 100VDC | Class gPV |
| PV-200A-2XL-B-15 | 200A | 1500V | — |
15 models in the PV family, sorted by rated current.
IEC 60269 UL Listed CSA Certified — as listed by the manufacturer for this catalog number. Confirm the current certificate before design freeze.
Array Protection.
DC string protection in photovoltaic arrays.
PV fuses must be rated for DC and derated for ambient temperature above 25 °C.
The fuse rating should sit between the string's maximum current and the module's series fuse rating.
What is the PV-110ANH1 rated for?
It is rated 100VDC at 110A. The interrupting rating is 50kA. It is a Class gPV fuse.
What class is this fuse?
Class gPV.
Can I replace it with a different class?
No. Fuse classes differ in dimensions and rejection features, so a different class will not fit the holder and may not provide the same protection.
What does the interrupting rating mean?
It is the maximum fault current the fuse can safely interrupt. It must be at least as high as the available fault current at the installation point.
How do I verify the part number?
Order by the full catalog number PV-110ANH1; suffixes change the terminal, voltage or package.
Where can I find the datasheet?
The manufacturer datasheet is the authority for derating curves, I²t and agency approvals for this catalog number.
Source: manufacturer catalog page for PV-110ANH1. Verify ratings against the current datasheet before ordering.
Shenzhen Gaorunxin Technology Co., Ltd