PV15M-4A-CT Eaton Bussmann 1500V 4A gPV Solar PV Fuse
PV15M-4A-CT Eaton Bussmann 1500V 4A gPV Solar PV Fuse

PV15M-4A-CT Eaton Bussmann 1500V 4A gPV Solar PV Fuse

Share
Eaton Bussmann PV15M-4A-CT, 1500V, 4A solar pv fuse, Panel interrupting.
    • Product Details
    • Download
    At a Glance
    • Rated current 4A
    • Rated voltage 1500V
    • Interrupting rating Panel
    • gPV class

    The Eaton Bussmann PV15M-4A-CT is a solar pv fuse rated 1500V at 4A and with a Panel interrupting rating. It is used for DC string protection in photovoltaic arrays. 1500VDC 4A in-line, Solar Fuse, Specialty Fuse, PV, Eaton Bussmann series photovoltaic fuse,DC Fuse.

    Key Specifications

    Product NameEaton Bussmann series photovoltaic fuses
    Catalog NumberPV15M-4A-CT
    Rated Amperage4A
    Rated Voltage1500V
    Product Height10.31 mm
    Product Length81.4 mm
    Product Width10.31 mm
    Product Weight13g
    ClassgPV
    Voltage TypeDC
    Suitable ForBMM Fuse block HEB Inline holder
    Fuse TypeSolar Fuse
    Breaking CapacityPanel
    3D Model / CADContact us
    CertificationGB15166

    Same-Series Models

    ModelCurrentVoltageClass
    PV15M-4A-CT4A1500VgPV
    PV15M-XXX-H63A1500V—
    PV15M-63-1500VDC63A1500V—
    PV15M-100100A1500V—
    PV15M-400-1500VDC400A1500V—

    5 models in the PV15M family, sorted by rated current.

    Standards & Approvals

    GB15166 — as listed by the manufacturer for this catalog number. Confirm the current certificate before design freeze.

    Applications

    DC string protection in photovoltaic arrays.

    Selection Notes

    PV fuses must be rated for DC and derated for ambient temperature above 25 °C.

    The fuse rating should sit between the string's maximum current and the module's series fuse rating.

    Common Questions

    What is the PV15M-4A-CT rated for?

    It is rated 1500V at 4A. The interrupting rating is Panel. It is a gPV fuse.

    What class is this fuse?

    gPV.

    Can I replace it with a different class?

    No. Fuse classes differ in dimensions and rejection features, so a different class will not fit the holder and may not provide the same protection.

    What does the interrupting rating mean?

    It is the maximum fault current the fuse can safely interrupt. It must be at least as high as the available fault current at the installation point.

    How do I verify the part number?

    Order by the full catalog number PV15M-4A-CT; suffixes change the terminal, voltage or package.

    Where can I find the datasheet?

    The manufacturer datasheet is the authority for derating curves, I²t and agency approvals for this catalog number.

    Source: manufacturer catalog page for PV15M-4A-CT. Verify ratings against the current datasheet before ordering.

    Shenzhen Gaorunxin Technology Co., Ltd